SPRAY & PUMP FAQ
1.
Why does the pump not run all the time?
This is an on- demand pump and only runs with flow; spray wand, by-pass, spray tips
or leak in system.
2.
Why does the pump surge while using the spray wand?
Low flow/high pressure may cause the pump to surge (or cycle). This could happen
when the spray wand is adjusted for a small or fine spray pattern. To overcome, adjust
the nozzle for higher flow.
3.
How do I adjust the pressure?
Pressure can only be adjusted by adjusting the nozzle.
4.
My pump quit and will not restart - what should I check?
Check all electrical connections. Ensure switch is in the on position. Check in-line fuse.
Ensure correct voltage (12-13 volt).
5.
Low flow or no flow at all - what should I check?
Check for a clogged suction hose and/or suction strainer. Often you will need to clean
the suction strainer. Check for proper voltage. Check filter in shut-off.
6.
Is there a fuse for the sprayer?
Yes, an in-line fuse, in the wire harness.
7.
What size fuse should I use as a replacement?
7.5 amp
8.
What is the range of the spray wand?
30 foot max
9.
How should I clean the tank after use?
•
Rinse tank thoroughly with water only, empty, refill with water.
•
Empty sprayer by spraying no less than 1 minute to rinse out line. The remaining
water can be drained per the drain plug.
•
Store sprayer tank upside down, in a warm dry location.
10. Can the spray tip on the wand be replaced with a different type of tip?
Yes, however your wand comes with a #18 tip which is standard. Brass tips generally
produce better spray patterns than plastic.
11. Each time I turn on the pump my fuse blows.
•
Excessive voltage
•
Improper adjustment of the pressure switch
•
Damaged wiring harness
12. What is the warranty (time duration) on pump, tank, and accessories?
1 year after purchase.
Chapin Spot Sprayer Operator's Manual - English
6E