CONNECTIONS

DEFAULT SETTINGS

Language: French
PASSWORD = Not programmed
Delay On: 0 minutes
Broken Hose: active
TAL: 0 unit (disabled)
Flow: Normally Open
Temperature: 25°C
pH:
• Dosing: Proportional
• SetP (setpoint): 7.2 pH
• T.MAX (maximum threshold):8.2pH
• Flow.Max (maximum flowrate): 80%
• Delay On: 3 sec (0-999sec)

DEFAULT SETTINGS RESTORE

3sec
Rev 0.3
A - Power cable, 90-250V-50-60Hz
B - ON/OFF switch.
C - BNC connector for pH probe or Rx probe.
D - BNC connector for temperature probe.
E - Flow sensor connector (3 and 4 contacts).
F - Level probe connector (3 and 4 contacts).
Rx:
• Dosing: Proportional
• SetP (setpoint): 730mV
• T.MAX (maximum threshold): 630mV
• Flow.Max (maximum flowrate): 80%
• Delay On: 3 sec (0-999sec)
Keep pushing for 3 seconds the ENTER / MENU button to
enter into the programming menu.
Move the cursor > to Utility by pressing ▼. Push ENTER
button to enter the submenu.
Push ▼ button to move the cursor to "Reset".
Push ENTER button to confirm.
By pushing the ▼ button choose "YES" to confirm and push
ENTER button.
Choose to restore the "Programming Parameters". Press
ENTER.
Automatically the pump restores the factory settings.
Press the ESC button for 3 seconds to exit programming.
Cod. 00.009.157
25