SCU100 INSITE PRO M COMPACT MANUAL DE USO
8.Access to control unit
Static access with default factory setting
1
2
3
4
5
For the first setup you have to use the direct LAN connection. Follow instructions under section "Direct
LAN Connection"
Check the internal time of the device. If it is not correct, it has to be set manually. For further information
about manual time setting, see "Settings-General-Time".
8.1.Network connection
The following sections show the steps needed to set up the SCU100 control unit.
The control unit can be used in different operating modes:
• LAN connection via router
• Direct LAN connection
• Additionally, data are available through serial port Modbus RTU (RS485). For further information,
consult the dedicated document.
LAN connection via router
The SCU100 control unit is connected to the router using a RJ45 cable (network).
Access to web user interface with default IP of control unit
Define static IP address for PC, for example:
Make sure the IP address in the assigned LAN is not used twice.
If it is used twice, an adjustment is required.
Subnet Mask
DHCP access
Note: If you change after initial commissioning for DHCP access
Download latest software version here:
https://search-ext.abb.com/library/Download.aspx?DocumentID=9AK-
K107680A3552&LanguageCode=en&DocumentPartId=&Action=Launch
Details
192.168.1.200:8000
192.168.1.5
192.168.1.x (x = 2...199,
201...255)
255.255.255.0
Hostname: Insite