Beko BHCB 61632 XH Manual Del Usuario página 9

Ocultar thumbs Ver también para BHCB 61632 XH:
Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 17
3
Operation of the Appliance
3.4 Replacement of Lamp
(Figure 3)
Make the electrical connections of the appli-
ance. Your appliance uses 3W spot LED lamp.
For replacing the lamps, push downwards
on the holder from its behind, turn it coun-
ter-clockwise, and take it out downwards.
Apply the above operation in reverse to install
new lamps (Figure 3).
Bulb
Bulb Power (W)
Holder / Socket
Bulb Voltage (V)
Size (mm)
ILCOS Code
Cooker Hood / User Manual
3
GZ 10
220 - 240
53 x 50
DR/F3-220-240-
GZ10-50-53
3.5 Operation with
Chimney Connection
Vapour is extracted through
the flue duct, which is fas-
tened to the connection head on the hood.
The diameter of the flue duct must be the
same as the connection ring. In horizontal
settings, the pipe has to have a slight up-
ward slope (around 10º) so that the air can
exit the room easily.
3.6 Operation without Chimney
Connection
Air is filtered through the
carbon filter and recirculated
in the room. Carbon filter is
used when it is impossible to
use a flue in the house.
In flueless use, remove the flaps inside the
flue adapter.
Remove the aluminum grease filter. To in-
stall the carbon filter, fit the filter to the tabs
by centring it on the plastic piece on both
sides of the fan body. tighten it by turning
right or left.
Replace aluminum grease filter.
9 / EN

Publicidad

Tabla de contenido
loading

Tabla de contenido