12 . Technical specifications

Dimensions
(Ø × D)
Spot ONE: Ø 97 × 175 mm
(W × H × D)
Spot DUO: 98 × 247 × 175 mm
Input voltage
220-240 V, 50/60Hz
Output
• Stand by
approx. 0.5 W
• Operation
approx. 0.5 W + LED lamp
Lamp
GU10-LED lamp (max. 9 W)
Sensor technology
Passive infrared
Detection zone
• Angle of coverage
90°
• Angle of aperture
90°
Reach
max. 10 m
Time setting
8 s - 35 min (Spot ONE/DUO Sensor only)
5 s - 60 min (Spot ONE/DUO Sensor Connect only)
Twilight setting
2-1000 Lux (Spot ONE/DUO Sensor only)
2-2000 lux (Spot ONE/DUO Sensor Connect only)
IP rating
IP44
Protection class
I
Temperature range
-20°C - +40°C
Bluetooth frequency
2.4-2.48 GHz (Spot ONE/DUO Sensor Connect only)
Bluetooth transmitter power 5 dBm/3 mW (Spot ONE/DUO Sensor Connect only)
22
13 . Troubleshooting
Malfunction
Cause
LED light does not switch ON ■ Fuse has tripped, not
switched ON, break in
wiring
■ Short circuit
■ Lamp faulty
Sensor-switched LED light
■ Twilight setting in
does not switch ON
night-time mode during
daytime operation
■ Mains switch OFF
■ Fuse has tripped
■ Detection zone not
correctly adjusted
Sensor-switched LED light
■ Continued movement
does not switch OFF
within the detection zone
Sensor-switched LED light
■ Animals moving in
keeps switching ON/OFF
detection zone
Sensor-LED light switches
■ Wind is moving trees and
ON when it should not
bushes in the detection
zone
■ Cars in the street are
detected
■ Sudden temperature
changes due to weather
(wind, rain, snow) or air
expelled from fans, open
windows
■ Sensor-switched LED
light is swaying (moving)
due to gusts of wind or
heavy rain
Remedy
■ Activate, change fuse,
turn ON mains switch,
check wiring with
voltage tester
■ Check connections
■ Change lamp
■ Reset
■ Switch ON
■ Activate, change fuse,
check connection if
necessary
■ Readjust
■ Check zone and
readjust if necessary or
apply shroud
■ Tilt sensor higher; adjust
detection zone
■ Change detection zone
■ Change detection zone
■ Adjust detection zone or
install in a different place
■ Mount sensor-switched
LED light on a firm
surface