Haier HSU-24H03/Z Manual De Funcionalmiento página 16

Ocultar thumbs Ver también para HSU-24H03/Z:
Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

Trouble shooting
Floor fixing dimensions
of the outdoor unit
(Unit:mm)
Before asking for service, check the following first.
The system does not restart
HSU-09H03/R2(DB)
immediately.
HSU-12H03/R2(DB)
HSU-12HB03/R2(DB)
HSU-18H03/R2(DB)
HSU-12HD03/R2(DB)
Fixing of outdoor unit
Noise is heard
Normal
Performance
Indoor Unit
inspection
Place, robust not causing vibration, where the body can be supported
sufficiently.
Place, not affected by heat or steam generated in the vicinity, where
inlet and outlet of the unit are not disturbed.
Place, possible to drain easily, where piping can be connected with the
Smells are generated.
outdoor unit.
Place, where cold air can be spread in a room entirely.
Place, nearby a power receptacle, with enough space around. (Refer
to drawings).
Mist or steam are blown out.
Place where the distance of more than lm from televisions, radios,
wireless apparatuses and fluorescent lamps can be left.
In the case of fixing the remote controller on a wall, place where the
indoor unit can receive signals when the fluorescent lamps in the room
are lightened.
Does not work at all.
Multiple
check
Poor cooling
Before inserting power plug into receptacle, check the voltage without fail. The power source is the same as the corresponding name p
Install an exclusive branch circuit of the power.
A receptacle shall be set up in a distance where the power cable can be reached. Do not extend the cable by cutting it.
Application temp. range of air conditioner -7
To this unit, both liquid and gas pipes shall be insulated
as they become low temperature in operation.
Use optional parts for piping set or pipes covered with
equivalent insulation material.
The thickness of the pipe must be 0.8mm at least.
Phenomenon
Fix the unit to concrete or block with bolts( 10mm) and nuts firmly and horizonta
When fitting the unit to wall surface, roof or rooftop, fix a supporter surely with na
or wires in consideration of earthquake and strong wind.
If vibration may affect the house, fix the unit by attaching a vibration-proof mat.
Selection of Installation Place
Power Source
Selection of pipe
o
113.5
Floor fixing dimensions
of the outdoor unit
(Unit:mm)
Cause or check points
When unit is stopped, it won't restart
immediately until 3 minutes have elapsed
to protect the system.
When the electric plug is pulled out and
reinserted, the protection circuit will work
for 3 minutes to protect the air conditioner.
During unit operation or at stop, a swishing
or gurgling noise may be heard. At first 2-3
minutes after unit start, this noise is more
noticeable. (This noise is generated by
refrigerant flowing in the system.)
During unit operation, a cracking noise may
be heard. This noise is generated by the
casing expanding or shrinking because of
temperature changes
Should there be a big noise from air flow in
Place, which is less affected by rain or direct sunlight and
sufficiently ventilated.
unit operation, air filter may be too dirty.
Place, possible to bear the unit, where vibration and nois
not increased.
This is because the system circulates smells
Place, where discharged wind and noise do not cause a
from the interior air such as the smell of
nuisance to the neighbors.
Place, where a distance marked
furniture, cigarettes.
in the above figure.
During COOL or DRY operation, indoor unit
may blow out mist. This is due to the sudden
cooling of indoor air.
Is power plug inserted?
Is there a power failure?
Is fuse blown out?
Is the air filter dirty? Normally it should be
cleaned every 15 days.
Are there any obstacles before inlet and outlet?
Is temperature set correctly?
Are there some doors or windows left open?
Is there any direct sunlight through the
window during the cooling operation?(Use
curtain)
Are there too much heat sources or too many
people in the room during cooling operation?
o
C~43
C.
15
Liquid pipe
Gas pipe
583
113.5
HSU-22H03/R2(DB)
Outdoor Unit
HSU-12H03/R2(DB)
HSU-09H03/R2(DB)
HSU-12HB03/R2(DB)
HSU-18H03/R2(DB)
HSU-12HD03/R2(DB)
HSU-22H03/R2(DB)
6.35mm(1/4")
6.35mm(1/4")
9.52mm(3/8")
12.7mm(1/2")
is available as illustr

Publicidad

Tabla de contenido
loading

Tabla de contenido