CHARGING A HOT OR COLD BATTERY PACK
If the battery pack is out of the normal temperature range, LED 3# will shine RED. When
the battery pack cools down to approximately 135°F (57°C) or warms to more than
37°F (3°C), the charger will automatically begin charging and the corresponding LEDs
on the charger will sequence normally.
DEFECTIVE BATTERY PACK OR CHARGER
If the charger detects a problem, LED 3# will begin flashing RED or all the LEDs will
turn off.
1. If registering as defective, remove and reinsert the battery pack in the charger.
If the LEDs still read "defective" a second time, try charging a different battery
pack.
2. If a different battery pack charges normally, dispose of the defective battery pack
(refer to the instructions in the battery pack manual).
3. If a different battery pack also indicates "defective", unplug the charger and wait
until the flashing LED 3# goes out, then reconnect the charger plug to the power
supply. If no charger LEDs shine green briefly simultaneously for self-inspection
at the plugging moment or LED 3# on charger still display defective, the charger
may be defective.
WALL-MOUNT HOLES
The charger has hanging holes for convenient storage (see Fig.1b). Install screws in the
wall 3 inches (76mm) apart. Use screws sufficiently strong to hold the combined weight
of the charger and battery pack.