Kohler K-8816 Manual Del Usuario página 7

Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

Control
Flange
Apply
Plumbers
Putty.
7. Install the Drain Control
CAUTION: Risk of poor product performance. Location of the cable drain control on the faucet deck
is critical to product performance. Make sure the 27" (68.6 cm) control body will reach the sink drain
before the cable drain control is installed.
Remove the control flange from the control housing and apply a ring of plumbers putty or other
sealant around the bottom of the control flange according to the putty manufacturer's instructions.
Assemble the flange nut, plastic washer and gasket to control housing. The distance between the top
of the control housing and gasket must be larger than the faucet deck thickness.
From under the sink, lift the control housing up to faucet deck and turn the control flange until
tight.
Align position of control housing as previously determined.
Push the control flange onto the sink.
Tighten the flange nut and remove excess putty or sealant.
8. Complete the Strainer Installation
Apply thread sealant tape to the control body.
Slide the nut onto the tailpiece and insert the small gasket.
Thread the tailpiece to the control body and tighten the nut securely with a wrench.
Kohler Co.
Control Knob
Indicator
Control Knob
Gasket
Plastic
Washer
Flange
Nut
Control
Housing
7
Control Body
Cable
(Assembled
to Control)
Gasket
Tailpiece
Nut
113776-2-AB

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

K-8817

Tabla de contenido