Input Photo 1; Input Photo 2; Photocell Operational Test - V2 PD5 Manual Del Usuario

Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

It is necessary to install the photocell 1 properly, in order to cover the action space of the gate.
no
the opening of PHOTO1 is not available
APCh
the opening of PHOTO 1 is available for the connection of the photocell
Cost
the opening of PHOTO 1 is available for the connection of the rib.
INPUT PHOTO 1 (INTERNAL PHOTOCELLS)
This input can be activated for the connection of
two different safety devices: the photocell or the rib.
The rib (contact normally closed) is an active safety
device in opening and closing (now active during
the backlash): its intervention during the opening
phase stops the gate, inverts the motion for 4 s,
without offsetting the doors. On the other hand, the
intervention of the rib in closing phase stops the
gate, inverts the motion with the offset of the doors.
The photocell 1 (contact normally closed) is an
active security in opening and closing: the
intervention of the photocell during the closing
stops the gate, at its disengagement the gate
inverts the motion.
Differently the intervention of the photocell in
opening stops the gate, at its disengagement the
gate starts opening again.
INPUT PHOTO 2 (EXTERNAL PHOTOCELLS)
The photocell 2 is active in closing: if it is dimmed
during the closing it stops the gate and inverts the
motion. The option CFCh activates the photocell
even when the gate is still: closed gate means that
no impulse has been given, either it is in pause or it
has received a STOP command. In this case
through all the time of the darkening of the
photocell the control unit does not receive any
command of activation at any opening / closing
cycle.
CFCh
the input PHOTO 2 is available: the
photocell is active in closing and also
when the gate is still
Ch
the input PHOTO 2 is available: the
photocell is active only during the closing
no
the input PHOTO 2 is not available

PHOTOCELL OPERATIONAL TEST

In order to achieve a safer operation for the user,
the unit performs a photocell operational test,
before a normal working cycle.
If no operational faults are found, the gate starts
moving. Otherwise, it will stand still while the
flashing light will stay on. The whole test cycle lasts
less than one second.
no
the test function is not active
Si
the test function is active
IMPORTANT: Connect power supply
cables of photocells transmitter between
terminals 11 and 12 of the control unit.
39

Hide quick links:

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

Pd7

Tabla de contenido