In order to weld in MIG Manual mode always choose the curve for the wire/diameter/gas to be used beforehand.
Set the motor m/min (metres per minute). Select the welding voltage shown on the display, press the knob for longer
than 1 second. This will display the set voltage in relation to the curve m/min. The machine adjusts to the V (voltage)
and m/min (metres per minute) settings.
Now the wire speed can be increased without changing the arc voltage. This process is active only for welding in
Short mode�
8

MMA WELDING

Connect the electrode holder cable connector to socket 16 and the earth cable connector to connector 4 (observing
the polarity stated by the electrode manufacturer).
In order to prepare the machine for MMA welding, follow the instructions previously described in the menu.
9

ERROR CODES

Error management is divided into two categories:
1)
Hardware errors [E]. These cannot be reset and require the power source to be restarted. These are displayed on
the screen with a red background.
2)
Alarms [W] linked to an external condition that can be reset by the user and does not require the generator to be
restarted.
These are displayed on the screen with an amber background.
Code
Type
2
[E]
6
[E]
9
[E]
10
[E]
11
[E]
14
[E]
20
[E]
22
[E]
24
[E]
24
[E]
25
[E]
26
[E]
56/58
Error Description
EEPROM error detected by the
power source internal board
Communication error detected
by master panel board on
CAN-bus
Communication error detected
by slave board on CAN-bus
Power output nil (I=0A, V=0V)
Overload at output
Undervoltage error detected
on inverter control board.
Interlock signal absent
Hardware key not readable
Error during reprogramming of
the EPLD or FPGA
Error during reprogramming of
the EPLD or FPGA
Excessive
primary
current error
Time not set or battery flat
Switch the power source off and on. If the problem
persists, contact technical assistance.
Switch the power source on and off. If the error persists,
contact technical assistance.
Switch the power source on and off. If the error persists,
contact technical assistance.
Hardware error, contact technical assistance. Probable
break in inverter circuit of primary winding or secondary
unit
Hardware error, contact technical assistance.
Check machine supply voltages. If the problem persists,
contact technical assistance.
Switch the power source off and on. If the problem
persists, contact technical assistance
Switch the power source on and off. If the error persists,
contact technical assistance.
Switch the power source on and off. If the error persists,
contact technical assistance.
Switch the power source on and off. If the error persists,
contact technical assistance.
winding
Switch the power source on and off. If the error persists,
contact technical assistance. Probable break in output
diodes or primary winding inverter circuit.
Turn the power source off and on. Replace the battery
on the panel board and contact technical assistance if
the error persists.