STEP 6: INSTALL NEW FILL VALVE
A:
INSTALL SHANK WASHER
Pull up to top of shank.
* Place shank washer onto
threaded shank of fill valve.
WIDE SIDE UP.
B:
PUSH REFILL TUBE ONTO REFILL
PORT FIRST
Squeeze tube clamp arms and move it
towards refill port.
C:
ATTACH REFILL CLIP TO OTHER END
OF REFILL TUBE
D:
INSERT FILL VALVE
Position refill tube to face flush valve making sure fill
valve parts do not interfere with lever arm.
Fill Valve
Refill Tube
Overflow
Pipe
Lever Arm
E:
ATTACH REFILL CLIP TO OVERFLOW PIPE
Note: If refill tube is too long to fit inside tank
with lid closed, remove refill tube from fill valve
refill port, cut tube, and reattach to port.
F:
INSTALL LOCKNUT
Screw locknut to the right
(counterclockwise) onto fill valve shank (below tank).
*Hand-tighten only. DO NOT OVERTIGHTEN.
8
Shank Washer
Threaded Shank
Refill Tube
TOP
DOWN
VIEW
Scissors
(Optional)
RIGHT
STEP 7: FINISHING STEPS
A: ATTACH WATER SUPPLY
CONNECTOR TO FILL VALVE
Twist to the right
(counterclockwise)
*Hand-tighten only.
DO NOT OVERTIGHTEN.
Clamp Arms
B:
TURN ON WATER
Check for leaks.
Refill
(Go to www.Fluidmaster.com/support
Port
for leak solutions.)
Refill Clip
C: WATER LEVEL
After the tank stops filling, water level should fill the tank to
roughly ½ inch below top of overflow pipe to ensure a
proper flush. (Does not need to be exact.)
**Lever Hole
*
Overtightening may damage fill valve or coupling nut, potentially causing flooding. Make sure
the float cup does not touch the tank walls or tank lever and flush valve.
**
The top of the overflow pipe must be a minimum of 1" below tank lever hole.
RIGHT
TURN
COUNTER-
CLOCKWISE
Top of
Overflow Pipe
1/2"
Water Level
Overflow Pipe
9