Ambient temperature during operation
A temperature range of -20° C bis 60° C is approved for operation.
Do not downgrade BIOS
Do not downgrade to an earlier version, e.g. from BIOS V02.08_01.00 to BIOS V02.05_16.02.
NOTICE
BIOS was downgraded anyway
After a downgrade, the Open Controller is unusable!
Please send the device in its original packaging to your Siemens representative.
Time-of-day synchronization cannot be used in the TIA Portal
The "Time-of-day synchronization" entry in the Inspector window > Properties > General cannot be used.
Changes to chapter 9.1: Status and error display – Power LED section
The behavior of the Power LED on shutdown of the operating system has changed.
POWER LED
LED off
LED lit yellow
LED lit green
Changes to chapter 11.2: Partitioning the CFast card
The following partitions are set up on the CFast card by default in delivery state:
Partition
C:
D:
E:
-
-
Changes to chapter 11.5: Windows language packages
Provided language packages
Chinese (Simplified)
German
English
French
Italian
Spanish
Storage location of the language packages
The language packs are available on the restore partition E: under \LanguagesPackages\.
12
Name
SYSTEM
DATA
Restore
-
WinCCMB
Product information on CPU1515SP PC2 (F/T/TF) and CPU1515SP PC2 (F) Ready4Linux
No supply voltage or supply voltage too low
Operating system is shut down
Supply voltage present;
Running through BIOS phase;
Supply voltage present;
Booting or operation of the operating system
128 GB CFast card
60 GB
44 GB
16 GB
0.4 GB
0.04 GB
Meaning
File system
NTFS
NTFS
NTFS
RAW
NTFS