4) LIMIT SWITCH SETTING
WARNING: before opening the door, the spring must be unloaded (vertical
boom). The barrier is provided with programmable electronic limit switches
and mechanical stop devices. There must be a rotation margin (about 1°) on
closing and opening between the electrical limit switches and mechanical
stop devices (Fig. J1). The adjustment is carried out as follows:
The end-of-stroke opening and closing positions must be set by modifying
the parameters of the control panel for Opening value Calibration and Clos-
ing value Calibration: if the value is increased, the end-of-stroke positions
move towards the opening direction. The extent of the movement depends
on the effective boom length: in the case of a 6-m boom, a unit change (1.0)
entails a movement of about 4,4 cm which, proportionally, becomes about
5,8 cm for an 8-m boom.
The effective closing value also depends, in part, on the manoeuvring speed.
It is therefore convenient to proceed to end-of-stroke calibration only after
having set the other opening parameters.
To evaluate correctly the values set, you are advised to carry out a few com-
plete consecutive manoeuvres.
4.1) POSITIONS OF THE LIMIT SWITCH SCREWS (Fig. J2)
5) SAFETY DEVICES
Note: only use receiving safety devices with free changeover contact.
5.1) TESTED DEVICES Fig. N
5.2) CONNECTION OF 1 PAIR OF NON-CHECKED PHOTOCELLS FIG. H1
5.3) CONNECTION OF 1 PAIR OF CHECKED PHOTOCELLS FIG. H2
6) ACCESS TO THE SIMPLIFIED MENU: FIG.1
6.1) CALLING UP MENUS: FIG. 2
6.2) PARAMETERS MENU (PARA ) (PARAMETERS TABLE "A")
6.3) LOGIC MENU (LOGIC) (LOGIC TABLE "B")
6.4) RADIO MENU (radio) (RADIO TABLE "C")
-
IMPORTANT NOTE: THE FIRST TRANSMITTER MEMORIZED MUST BE
IDENTIFIED BY ATTACHING THE KEY LABEL (MASTER).
In the event of manual programming, the first transmitter assigns the RECEIVER'S
KEY CODE: this code is required to subsequently clone the radio transmitters.
The Clonix built-in on-board receiver also has a number of important advanced features:
Cloning of master transmitter (rolling code or fixed code).
Cloning to replace transmitters already entered in receiver.
Transmitter database management.
Receiver community management.
To use these advanced features, refer to the universal handheld programmer's
instructions and to the general receiver programming guide.
6.5) DEFAULT MENU (default)
Restores the controller's DEFAULT factory settings.
6.6) LANGUAGE MENU (language)
Used to set the programmer's language on the display.
TABLE "A" - PARAMETERS MENU - (PARA )
Parameter
min.
max.
0
180
TCA
1
180
TRF. L GHT. C LR. T
0
240
alar ti e
o p e n . c a l i b .
0
100
(Special par. 1)***
c l o s . c a l i b .
0
100
(Special par. 6)***
accel.
1
5
(Special par. 6)***
45
99
DIST. D ECEL
40
99
OP. F ORCE
40
99
CLS. F ORCE
30
GIOTTO BT A ULTRA 36
Default
Personal
Definition
10
Automatic closing time [s]
Time-to-clear traffic light zone
40
Alarm time
30
Opening value calibration
60
Closing value calibration
45
2
Acceleration
55
Deceleration distance [%]
Leaf force during opening
75
Leaf force during closing
75
ENGLISH
6.7) STATISTICS MENU (STAT)
Used to view the version of the board, the total number of operations (in
hundreds), the number of transmitters memorized and the last 30 errors (the
first 2 digits indicate the position, the last 2 give the error code). Error 01 is the
most recent.
6.8) PASSWORD MENU (PASSWORD)
Used to set a password for the board's wireless programming via the U-link network.
With "PROTECTION LEVEL" logic set to 1,2,3,4, the password is required to access
the programming menus. After 10 consecutive failed attempts to log in, you will
need to wait 3 minutes before trying again. During this time, whenever an attempt
is made to log in, the display will read "BLOC". The default password is 1234.
7) CONNECTION WITH EXPANSION BOARDS AND UNIVERSAL HANDHELD
PROGRAMMER VERSION> V1.40 (Fig. K) Refer to specific manual.
WARNING! Incorrect settings can result in damage to property and injury to people
and animals.
8) U-LINK OPTIONAL MODULES
Refer to the U-link instructions for the modules.
9) Opposite Barriers
Refer to the U-link instructions for the modules.
NOTE: On the board set as the Slave, the Safety Edge input (Safety Edge/ Test
Safety Edge/ 8k2 Safety Edge) should only be set to SAFE2.
10) RESTORING FACTORY SETTINGS (Fig.
WARNING: this operation will restore the control unit's factory settings and all
transmitters stored in its memory will be deleted.
WARNING! Incorrect settings can result in damage to property and injury to
people and animals.
- Cut off power to the board (Fig.
- Open the Stop input and press the - and OK keys together (Fig.
- Switch on the board's power (Fig.
- The display will read RST; confirm within 3 sec. by pressing the OK key (Fig.
- Wait for the procedure to finish (Fig.
- Procedure finished (Fig.
11) PARKING MANAGEMENT SYSTEM CONNECTION
The board has an output for the control of the barrier status configured this
way (Fig. H5).
The logic must be set to AUX3/AUX0=12 .
closed contact between terminals 26-27 with the barrier lowered
open contact between terminals 26-27 with the barrier not lowered.
12) EMERGENCY RELEASE (Fig. E)
WARNING! When an actuator without bar needs to be released, ensure
that the balancing spring is not compressed (bar in the opening position).
12
.1) LOCAL COMMANDS Fig.
While the display is off, pressing the + key commands the gate to Open and
pressing the - key commands it to Close. Pressing either key again while the
automated device is moving commands the gate to STOP.
Description
Waiting time before automatic closing.
Time-to-clear for the zone run through by traffic controlled by the traffic light.
[s]
If an obstacle is sensed or the photocells are engaged for longer than the set
time, the AUX contact configured as OPEN GATE ALARM output closes. The
[s]
contact is then opened by the Stop command or by the closing limit switch.
Opening value calibration [%]
Set the reference value from 0,0 to 100,0 for the required opening position
(see Paragraph Limit Switch Setting).
Closing value calibration [%]
Set the reference value from 0,0 to 100,0 for the required closing position
(see Paragraph Limit Switch Setting).
Acceleration [%]
Set the acceleration to be applied at the beginning of each movement.
Deceleration distance (switch from running speed to slow-down speed) for
motor(s) both during opening and during closing, given as a percentage of
total travel.
Force exerted by the barrier while opening.
WARNING: It affects impact force directly: make sure that
[%]
current safety requirements are met with the set value (*).
Install anti-crush safety devices where necessary (**).
Force exerted by the barrier while closing.
WARNING: It affects impact force directly: make sure that
[%]
current safety requirements are met with the set value (*).
Install anti-crush safety devices where necessary (**).
(Fig. L)
M
)
M
ref.1)
M
ref.3)
M
ref.5)
M
ref.6)
I
M
ref.2)
O
ref.4)