Measurement Preparation - Benning MM 3 Manuel De Instrucciones

Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 36
7.5 Resistance ranges
Overload protection for resistance measurements: 600 V
Range
Resolution
200 Ω
0,1 Ω
2 kΩ
1 Ω
20 kΩ
10 Ω
200 kΩ
100 Ω
2 MΩ
1 kΩ
20 MΩ
10 kΩ
7.6 Diode and Continuity Testing
The accuracy indicated below is valid in the range of 0.4 V to 0.9 V.
Overload protection for diode testing: 600 V
The built-in buzzer sounds if the resistance R falls below 50 Ω.
Range
Resolution
7.7 Capacitance ranges
Conditions: Capacitors must be discharged before testing and then connected
to the meter according to the indicated polarity.
Range
2 nF
20 nF
200 nF
2 µF
20 µF
200 µF
7.8 Frequency ranges
The frequency to be measured must have a minimum input signal of 200 mV
Range
Resolution
2 kHz
1 Hz
20 kHz
10 Hz
200 kHz
100 Hz
8.
Measuring with BENNING MM 3

8.1 Measurement preparation

The BENNING MM 3 must be used and stored only at the indicated storage and
working temperatures, avoid exposure to continuous sunlight.
-
Check the rated voltage and current indications on the test leads. The
safety test leads provided with the BENNING MM 3 correspond specifically
to the rated voltage and current of the BENNING MM 3.
-
Inspect the test leads for damaged insulation. If the insulation is damaged,
the test leads should be discarded immediately.
-
Check test lead continuity. If the conductor in the test lead is damaged, the
leads should be discarded immediately.
-
Remove test leads from circuit to be measured before turning the rotary
switch  to select another function.
-
If the BENNING MM 3 is used near strong noise generating sources, the
display may become unstable and measurement errors may arise.
09/ 2013
± (0.8 % of reading + 4 digits)
± (0.8 % of reading + 2 digits)
± (0.8 % of reading + 2 digits)
± (0.8 % of reading + 2 digits)
± (0.8 % of reading + 2 digits)
± (2 % of reading + 5 digits)
1 mV
± (1,5 % of reading + 5 digits)
Resolution
1 pF
± (2,0 % of reading + 4 digits)
10 pF
± (2,0 % of reading + 4 digits)
100 pF
± (2,0 % of reading + 4 digits)
1 nF
± (2,0 % of reading + 4 digits)
10 nF
± (2,0 % of reading + 4 digits)
100 nF
± (2,0 % of reading + 4 digits)
Accuracy for 5 V
± (1,0 % of reading + 3 digits)
± (1,0 % of reading + 3 digits)
± (1,0 % of reading + 3 digits)
BENNING MM 3
Accuracy
.
rms
Accuracy
Accuracy
max.
rms
.
rms
Maximum
test current
circuit voltage
2,5 mA
200 µA
40 µA
4 µA
400 nA
40 nA
Maximum
test current
circuit voltage
1,5 mA
Frequency
40 Hz
40 Hz
40 Hz
40 Hz
40 Hz
40 Hz
Minimum input
frequency
20 Hz
200 Hz
2 kHz
Max. open
3,2 V
0,5 V
0,5 V
0,5 V
0,5 V
0,5 V
Max. open
3,2 V
.
rms
Overload
protection
600 V
rms
600 V
rms
600 V
rms
14