Andis Sensa-Charge AGR+ Manual Del Usuario página 4

Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 15
SAFETY RULES FOR CHARGER AND
BATTERY PACK
1. The clipper motor switch must be in the "OFF" position for the
charger to operate properly. Do not return the clipper to the
charger base with the motor switch in the "ON" position. If the
clipper is accidentally put on the charger base in the "ON" position,
remove it promptly. Turn clipper off and return to the charger base.
2. Do not insert anything metallic into the battery pocket of the
charger base.
3. Do not allow the ventilation slots on the charger base to become
blocked or filled with foreign material. Avoid subjecting the charger
to excessively dirty locations. If the slots become clogged with dust
or hair, unplug charger and gently remove hair with a soft brush or
a vacuum cleaner.
4. Do not attempt to charge any other battery other than the battery
pack designed for your Andis AGR+ clipper.
5. The battery pack contains an overload protection feature. Do not
attempt to use it to power any other product other than the Andis
cordless clipper. Do not touch the exposed metal contacts on the
battery pack with any conductive material.
6. Do not store battery or charger where it is under 50°F or over
104°F, as damage may occur.
7. Do not expose the charger base or the battery pack to excessively
damp conditions.
8. Avoid dropping the charger base and the battery pack. Do not
attempt to use a damaged battery pack or charger.
9. Clean external parts of charger with a soft brush or damp rag.
Do not use harsh abrasives, detergents, or solvents.
GUIDELINES FOR CHARGER AND
BATTERY PACK
1. Your clipper, battery pack, and charger function has several
interacting electrical systems. Good electrical contact must be
maintained in order for the motor to deliver full power, the battery
to charge properly, and the Refresh feature to operate. Limited or
erratic performance caused by dirt or age can be restored in the
majority of the cases if you do the following:
A. Problem: Clipper motor starts and stops as if there was a loose
electrical connection.
Solution: Remove the battery pack from the clipper. Examine
the battery pack opening in the clipper. Locate the two sets of
motor contacts. Gently squeeze the metal leaves until they are
about 1/16" (1.6 mm) apart using a long pliers or similar. DO
NOT squeeze the metal leaves completely together or the
battery pack will not re-insert.
B. Problem: Charger does not fully charge the battery.
Solution: Clean the battery pack bottom contacts (the portion
inserted into the charging pocket). Clean the charger contacts.
Re-align the charger contacts. To clean the battery pack
contacts, rub gently with a pencil eraser until they are brightly
polished. Use a cotton swab and 91% isopropyl alcohol to
remove any residue or dirt. Denatured alcohol can also be used.
Use care, as both products are flammable. Clean the charger
contacts in the same way - UNPLUG CHARGER FIRST. Make
sure eraser dust and cleaners do not get inside the charger
base. To re-align the charger contacts, again make sure it is
unplugged, and gently pull the metal loops on the four contacts
forward SLIGHTLY. Do not severely bend, deform, or damage
the contacts.
C. Problem: Charger does not exit the Refresh mode.
Solution: Clean the battery pack bottom contacts as noted
above. Clean and re-align the charger contacts as noted above.
D. Problem: Charger lights flash on and off as clipper or battery is
moved side to side in the charger pocket.
Solution: Re-align the charger contacts as noted above.
4
A
B
BATTERY
RELEASE
C
Green Light
Fast Charge
Charging Complete
Refresh
Charge Preparation
Red Light
Charge Standby
(Analyzing Battery)
Please see instructions for further
details on SensaCharge System.
D
REFRESH
BUTTON

Publicidad

Tabla de contenido
loading

Tabla de contenido