Installation to Solid Concrete or Cinder Block

• When installing Peerless wall mounts on cinder block, verify that you have a minimum of 1-3/8" of actual concrete
thickness in the hole to be used for the concrete anchors. Do not drill into mortar joints! Be sure to mount in a solid
part of the block, generally 1" minimum from the side of the block. Cinder block must meet ASTM C-90 specifica-
tions. It is suggested that a standard electric drill on slow setting is used to drill the hole instead of a hammer drill to
avoid breaking out the back of the hole when entering a void or cavity.
• Concrete must be 2000 psi density minimum. Lighter density concrete may not hold concrete anchor.
• Make sure that the supporting surface will safely support the combined load of the equipment and all attached hard-
ware and components.
Refer to chart on page 1 to determine wall plate
4
configuration. Make sure that wall plate (AA) is level, use it
as a template to mark four mounting holes. The top
mounting hole should be 2.5" above the desired screen
center as shown in figure 4.1 on page 8. Drill four 1/4"
(6 mm) dia. holes to a minimum depth of 2.5" (64 mm).
Insert anchors (EE) in holes flush with wall as shown (right).
Place wall plate over anchors and secure with #14 x 2.5"
screws (DD). Level, then tighten all fasteners.
NOTE: Six holes and six sets of fasteners are required
when mounting the wall plate for equipment weighing
greater than 200 lbs or if your screen size is in the 50" to
84" range.
WARNING
• Tighten screws so that wall plate is firmly attached, but
do not overtighten. Overtightening can damage screws,
greatly reducing their holding power.
• Never tighten in excess of 80 in. • lb (9 N.M.).
WARNING
• Always attach concrete anchors directly to load-bearing
concrete.
• Never attach concrete anchors to concrete covered with
plaster, drywall, or other finishing material. If mounting to
concrete surfaces covered with a finishing surface is
unavoidable, the finishing surface must be counterbored
as shown below. Be sure concrete anchors do not pull
away from concrete when tightening screws. If plaster/
drywall is thicker than 5/8", custom fasteners must be
supplied by installer. (Not evaluated by UL)
INCORRECT
wall
plate
plaster/
dry wall
CORRECT
wall plate
concrete
plaster/
dry wall
WARNING
1
Drill holes and insert anchors (EE).
2
Place plate (AA) over anchors (EE) and secure with screws (DD).
3
Tighten all fasteners.
AA
DD
concrete
10 of 33
AA
DD
EE
ISSUED: 09-20-06 SHEET #: 202-9167-4 11-13-07
concrete
surface
EE
EE