Installation To Solid Concrete Or Cinder Block - PEERLESS SA761P Manual Del Usuario

Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

Installation to Solid Concrete or Cinder Block

• When installing Peerless wall mounts on cinder block, verify that you have a minimum of 1-3/8" (35 mm) of actual
concrete thickness in the hole to be used for the concrete anchors. Do not drill into mortar joints! Be sure to mount
in a solid part of the block, generally 1" (25 mm) minimum from the side of the block. Cinder block must meet ASTM
C-90 specifications. It is suggested that a standard electric drill on slow setting is used to drill the hole instead of a
hammer drill to avoid breaking out the back of the hole when entering a void or cavity.
• Concrete must be 2000 psi density minimum. Lighter density concrete may not hold concrete anchor.
• Make sure that the supporting surface will safely support the combined load of the equipment and all attached hard-
ware and components.
Use wall plate template to mark mounting holes. Top
3
mounting holes should be located 9.5" (241 mm) above
desired screen center as shown in figure 2.1 on page
5. Drill four 13/32" (10 mm) dia. holes 3" (76 mm) deep
as shown in fig. 3.1. Insert anchors (D) into holes flush
with wall as shown (right). Place wall arm over anchors
and secure with 5/16 x 3" screws (C). Level, then
tighten all fasteners.
WARNING
• Tighten screws so that wall plate is firmly attached,
but do not overtighten. Overtightening can damage
screws, greatly reducing their holding power.
• Never tighten in excess of 80 in. • lb (9 N.M.).
• Always attach concrete expansion anchors directly
to load-bearing concrete.
• Never attach concrete expansion anchors to
concrete covered with plaster, drywall, or other
finishing material. If mounting to concrete surfaces
covered with a finishing surface is unavoidable,
the finishing surface must be counterbored as
shown below. Be sure concrete anchors do not
pull away from concrete when tightening screws. If
plaster/drywall is thicker than 5/8" (16 mm), custom
fasteners must be supplied by installer.
INCORRECT
wall
plate
plaster/
dry wall
concrete
wall
plate
X
plaster/
dry wall
WARNING
1
Drill holes and insert anchors (D).
2
Place plate (A) over anchors (D) and secure with screws (C).
3
Tighten all fasteners.
SOLID CONCRETE
A
CORRECT
C
concrete
6 of 32
A
C
D
ISSUED: 03-30-10 SHEET #: 095-9346-1
concrete
surface
D
D
CINDER BLOCK
fig. 3.1

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

Sa761p-s

Tabla de contenido