Installation to Solid Concrete or Cinder Block

• when installing Peerless wall mounts on cinder block, verify that you have a minimum of 1-3/8" (35 mm) of actual
concrete thickness in the hole to be used for the concrete anchors. Do not drill into mortar joints! Be sure to mount
in a solid part of the block, generally 1" (25 mm) minimum from the side of the block. Cinder block must meet ASTM
C-90 specifications. It is suggested that a standard electric drill on slow setting is used to drill the hole instead of a
hammer drill to avoid breaking out the back of the hole when entering a void or cavity.
• Concrete must be 2000 psi density minimum. Lighter density concrete may not hold concrete anchor.
• Make sure that the wall will safely support four times the combined load of the equipment and all attached hardware
and components.
Use a level to draw a horizontal line 5 - 3/16"
1
(132 mm) above the desired screen center to locate
center points of the top mounting slots as shown in
figure 1.1 on page 4. Use wall plate as a template,
level wall mount and mark center of four mounting
holes. NoTe: Be sure arms of wall mount (A) are
fully extended to access slots. Drill four 5/16" (8
mm) dia. holes to a minimum depth of 2.5" (64 mm).
Insert anchors (D) in holes flush with wall, place wall
mount (A) over anchors and secure with 2.5" wood
screws (C) as shown right. Make sure wall mount
is level, and tighten all fasteners as shown in figure
1.3.
NoTe: Flanges of adapter plate indicate top of
mount.
WARNING
• Tighten screws so that wall plate is firmly attached,
but do not overtighten. Overtightening can damage
screws, greatly reducing their holding power.
• Never tighten in excess of 80 in. • lb (9 N.M.).
• Always attach concrete expansion anchors directly
to load-bearing concrete.
• Never attach concrete expansion anchors to
concrete covered with plaster, drywall, or other
finishing material. If mounting to concrete surfaces
covered with a finishing surface is unavoidable,
the finishing surface must be counterbored as
shown below. Be sure concrete anchors do not
pull away from concrete when tightening screws.
If plaster/drywall is thicker than 5/8" (16 mm),
custom fasteners must be supplied by installer (not
evaluated by UL).
INCoRReCT
concrete
wall
plate
plaster/
dry wall
WARNING
CoRReCT
concrete
wall
plate
plaster/
dry wall
1
Drill holes and insert anchors (D).
2
C
Place plate (A) over anchors (D) and secure with screws (C).
3
Tighten all fasteners.
SOLID CONCreTe
D
A
C
fLANge INDICATeS
concrete
surface
D
A
D
CINDer BLOCK
fig. 1.3