7.5 Sewage discharge
• Discharge the waste water with a PVC pipe Ø32
mm, which must be 430 mm from the floor (for a bowl
at 475 mm from the floor - see fig.1).
Note: the discharge pipe must also be held in place by
clamps.
7.6 Power supply
The electrical installation must be carried out by a qualified person.
be sure to comply with the provisions of the standard in force in the country
of use (UK : BS 7671) concerning the protection volumes in a bathroom.
8. WALL CASING
INFO: In the case of a non-supplied cladding such as plasterboard, refer to paragraph 8.2.
8.1 Preparation and installation of the wall casing
(see paragraph 9.3 for the remote button)
• Prepare a cut-out to allow the water injection passage according to the previously selected seat
height:
- for a half-height adjustment, the cut-out will be 40 mm;
- for an adjustment in the upper position, the cut-out will be 70 mm;
- for a low adjustment, no cut-out is necessary.
✱