Safety Notes; Technical Data; Replacement Parts - Grohe 36 324 Manual De Instrucciones

Ocultar thumbs Ver también para 36 324:
Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 9
GB

Safety notes

Prevent danger resulting from damaged voltage
supply cables.
If damaged, the voltage supply cable must be
replaced by the manufacturer or his customer service
department or an equally qualified person.
• Installation is only possible in frost-free rooms.
• The plug-in voltage supply is only suitable for indoor use.
• The plug-in connectors must not be directly or indirectly
sprayed with water when cleaning.
• The voltage supply must be separately switchable.
• Use only genuine replacement parts and accessories.
The use of other parts will result in voiding of the warranty
and the CE identification, and could lead to injuries.

Technical data

• Voltage supply:
• Power consumption:
• Automatic safety shut-off:
(6 - 420 s adjustable)
• Run-on time (0 - 19 s adjustable):
• Reception range according to Kodak Gray Card,
grey side, 8x10", landscape (7 - 20cm adjustable):
• Type of fitting protection:
Thermal disinfection possible.
Electrical test data
• Software class
• Contamination class
• Rated surge voltage
• Temperature of ball impact test
The test for electromagnetic compatibility (interference emission
test) was performed at the rated voltage and rated current.
If static pressures exceed 0.5 MPa, a pressure-reducing valve
must be installed.
Fault / Cause / Remedy
Fault
Water not flowing
Undesired water
flow
Flow rate too low
100-240 V AC 50-60 Hz/6.75 V DC
Cause
• Filter upstream of solenoid valve blocked
• Solenoid valve defective
• Plug-in connector without contact
• Power supply unit defective
• Sensor system detection zone set too high
for local conditions
• Automatic flushing activated
• Solenoid valve defective
• Mousseur dirty
• Filter upstream of solenoid valve dirty
• Filter in adapter dirty
Installation
Flush pipes thoroughly before and after
installation (observe EN 806)!
Open hot and cold water supply and check that
connections are watertight.
To protect the storage heater from excess pressure you
must install the flow regulating valve provided.
Filling the storage heater, see page 4.
Volume of water in storage heater will expand as it
is heated. Expansion water must drip out of the
mixer spout. This process is necessary and
normal.
The spout must not be fitted with any downstream
resistances in the form of aerators and compo-nents
reducing flow (e.g. restrictors) as these will result in
damage to the storage heater.
Setting temperature limiter,
see page 4.
Operation,
2.4 W
60 s
see technical product information 99.0438.xxx.
Activating setting mode
1 s
Disconnect the power supply to the electronics and reconnect
after 10 s.
12cm
The indicator lamp in the sensor system illuminates in setting
IP 59K
mode when the detection zone of the fitting is reached by an
approaching user.
Setting mode is automatically terminated after 3 minutes..
Maintenance
A
2
•Shut off hot and cold water supply.
2500 V
•Disconnect voltage supply.
100 °C
•Inspect and clean all components and replace if
necessary.

Replacement parts

see page 2 (* = special accessories)
Care
For directions on the care of this fitting, please refer to the
accompanying Care Instructions.
Remedy
- Clean filter
- Replace solenoid valve
- Check plug-in connector
- Replace power supply unit
- Reduce range using remote control (special
accessory, prod. no.: 36 407)
- Wait 1 - 10 minutes
- Replace solenoid valve
- Clean or replace mousseur
- Clean filter
- Clean or replace filter
, see page 3.
, see page 35.
6

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

36324001Eurosmart cosmopolitan e 36 324Eurosmart cosmopolitan e 36324001

Tabla de contenido