Electrical Connection; Downloading Further Instructions; Configuration - Balluff BTL5-T1 M P-S103 Serie Instrucciones Breves

Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 10
BTL5-T1_ _-M_ _ _ _-P-S103
Magnetostrictive Linear Position Sensor – Profile Style
The CE Mark verifies that our products
meet the requirements of the current
EMC Directive.
Intended use
The magnetostrictive linear position sensor BTL, together
with a machine controller (e.g. PLC) and an Profibus-
master, comprises a position measuring system. It is
intended to be installed into a machine or system and
used in the industrial sector. Flawless function in
accordance with the specifications in the technical data is
ensured only when using original Balluff accessories. Use
of any other components will void the warranty.
Opening the BTL or non-approved use are not permitted
and will result in the loss of warranty and liability claims
against the manufacturer.
General safety notes
Installation and startup may only be performed by
trained specialists.
The operator is responsible for ensuring that local safety
regulations are observed. In particular, the operator must
take steps to ensure that a defect in the BTL will not result
in hazards to persons or equipment.
If defects and unresolvable faults occur in the BTL, take it
out of service and secure against unauthorized use.

Downloading further instructions

A complete user's guide and the configuration guide can
be downloaded from the Internet at www.balluff.com or
requested via e-mail from service@balluff.de.
Dimensions and function
The BTL contains the waveguide which is protected by an
aluminum housing. A magnet is moved along the
waveguide. This magnet is connected to the system part
whose position is to be determined. The magnet defines
the position to be measured on the waveguide.
DIP switches S1 for
setting station address
1)
red
Groove
green
Mounting clamps with insulating bushes
and ISO 4762 M5x22 cylinder-head screws,
max. tightening torque 2 Nm
1
english
Null point
Nominal length =
Measuring range
2)
BTL5-P-3800-2
3)
magnet
1) Unusable area
2) Not included in scope of delivery
3) Groove on the top side of the profile marks the start of measuring range

Electrical connection

Control and data signals
Pin
BUS IN / OUT
1
VP +5 V (output)
2
RxD / TxD-N (A)
3
Data GND
4
RxD / TxD-P (B)
5
Shield
Power
(pin)
4
1
3
Bus Out
Bus In
(socket)
(pin)

Configuration

Station address: Values 0...127 allowed
Value 0...125 = station address
Value 126 = address 126 or the address set by
Set_Slave_Address
Value 127 = reset BTL to its default condition
S1.1
S1.2
S1.3
S1.4
2
0
2
1
2
2
LSB
1
2
4
Bus termination S1.9 and S1.10 = ON
End point
1)
UL approval
File No.
E227256
Supply voltage
(external)
Power
+24 V
0 V (GND)
Shield
S1.5
S1.6
S1.7
2
3
2
4
2
5
2
6
MSB
8
16
32
64

Publicidad

Tabla de contenido
loading

Tabla de contenido