(**) For the Open Gate LED, two operating modes and two connecting possibilities are provided.
The two operating modes are the following: the first as SCA, with slow flashing in the opening phase,
fixed light when the door is not closed, fast flashing in the closing phase and light off when the door is
completely closed. The second operating mode is as courtesy light. The light switches on at the begin-
ning of the movement and it switches off 160 seconds after the end of movement.
The two connecting modes are at 24Vac, between terminals 10 and 11 with J2 bond up and with a con-
tact free from relays between terminals 11 and 12 with J2 bond down.
Dip-switch functions
N.B.:
Every change of functions have to be done without electricity.
DSW1
The operating mode of the "P.P. button" and of the remote control is selected.
Off: Operation "OPEN" - "STOP" - "CLOSE"
On: Operation "OPEN" - "STOP" - "OPEN"
DSW2
The "Service man" function on the Open button is enabled or disabled
Off: Service man function disabled
On: Service man function enabled
DSW3
The "Service man" function on the Close button is enabled or disabled
Off: Service man function disabled
On: Service man function enabled
DSW4
The automatic closure is enabled or disabled
Off: Automatic closure disabled
On: Automatic closure enabled
DSW5
Forewarning flashing light is enabled or disabled
Off: Forewarning flashing light is disabled
On: Forewarning flashing light is enabled
DSW6
The type of activation of the "FTC" input in the opening phase is selected
Off: No activation
On: Temporary stop
DSW7
The multiple-flat function is enabled or disabled
Off: Multiple-flat function is disabled
On: Multiple-flat function is enabled
DSW8
The operation of the circuit-breaker is controlled if this device is activated before the minimum
time has elapsed.
Off: If the reversion is caused by a protection, the circuit-breaker is activated at the end of time-
out. If the cause is not a protection device, the system stops.
On: The reversion movement is carried out in any case, without the activation of the circuit-
breaker.
Trimmer functions
TCA
The automatic closure time can be adjusted when it is enabled by moving the Dip-Switch
DSW4=ON. The adjustment varies from 1 sec. minimum to 250 sec. maximum.
TL
The operating time of the system can be adjusted. After this time, the software protection is
activated should a failure of the limit switches occurs (position this trimmer at approx. 4 sec
more than the real stroke of the automatic system). The adjustment varies from 1 sec. minimum
to 250 sec. maximum.
Trimmer functions
These can be preset by using the programming push-button (PGM) along with the Dip-Switches.
Move the Dip-switch as shown in the table hereunder, press the button PGM for 2 seconds, release the
button, then move the Dip-switches in the desired configuration.
Function
Menu
Dip-switch 1÷4= On/Off/Off/Off
ON
1
2
3
4
Dip-switch5= Operation of SCA.
Off: Operation as SCA.
On: Operation as courtesy light (def.).
Dip-switch6= Faulty protections.
In the event protection devices (photocells and safety edge) no longer send the
enable signal to the system, the latter can be used in "Service man" mode. Even
though this function is not selected, this option can be enabled by keeping the push-
button pressed for at least 2 consecutive seconds.
Off: The automatic system is not activated until reset of protections.
On: After 2 sec. the automatic system starts in any case in "Service man" mode (def).