1
Cartridge Installation
A.
2
1
Turn off water supplies. Remove cover (1),
bonnet nuts (2) and test caps (3) from the rough-
in body (4) (R75000). Place a bucket or small
container over the front of the valve body and
slowly open the water supplies to flush any
debris from the supply lines before installing the
cartridge. Turn the water supplies back off.
Back to back Installation
Reverse
Installation
4
Cold
1
3
For back to back or reverse installations (hot on
right and cold on left) insert the cartridge (1) with
the "hot side" on the right. If you are not making
a reverse or back to back installation skip this
step and continue with step 1C. Apply silicone
lube to the three o-rings shown above to make
the cartridge easier to install and remove from the
rough-in body. Install the cartridge making sure
that the keys are fully engaged with the slot in the
rough-in body (see step B). Slide o-ring (3) and
bonnet nut (4) over the cartridge and thread onto
the rough-in body. Hand tighten securely.
4
3
R75000
3
2
Normal Installation
(changes not required)
Hot
T75P Series Installation
B.
2
4
1
Rotate the cartridge (1) so the words "hot side"
(2) appear on the left. Insert cartridge into valve
body as shown. Make sure the cartridge tubes
and O-rings (3) are properly seated in holes at the
base of the body. Ensure the keys on the body are
fully engaged with the slots in the body (4). A light
coating of plumbers grease applied to o-rings may
aid in assembly.
C.
1
Thread bonnet nut (2) onto cartridge. Hand tighten
securely. Slide o-ring (1) over the cartridge and
bonnet.
3
3
2
92658 Rev. A