Updating Firmware - Vimar ELVOX SW24.W Guía Rápida Para El Instalador

Tarjeta de mando con pantalla y receptor de radio 433 mhz incorporado
Ocultar thumbs Ver también para ELVOX SW24.W:
Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 44
SW24.W
List of signalling on the display
Signal
Description
C1
Contact closed on command C1 input
C2
Contact closed on command C2 input
C3
Contact closed on command C3 input
C4
Contact closed on command C4 input
S1
Contact open on safety device S1 input
S2
Contact open on safety device S2 input
S3
Contact open on safety device S3 input
S4
Contact open on safety device S4 input
FO1
Opening limit switch position reached motor 1
FC1
Closing limit switch position reached motor 1
FO2
Opening limit switch position reached motor 2
FC2
Closing limit switch position reached motor 2
OB1
Obstacle detected motor 1
OB2
Obstacle detected motor 2
AF1
Motor in stop approach force reduction interval
Motor 2 in stop approach force reduction in-
AF2
terval
MSO1
Mechanical stop reached in opening motor 1
MSC1
Mechanical stop reached in closing motor 1
MSO2
Mechanical stop reached in opening motor 2
MSC2
Mechanical stop reached in closing motor 2
Operation with battery. When this message is
BATT
displayed it is followed by an indication of the
battery operating voltage, e.g. 24.5V
Battery almost flat (indication shown only
BT-
when the gate is stopped)
Battery totally flat (indication shown only when
BT--
the gate is stopped)
Radio command received from saved remote
RX
control or from App
Radio command received from unsaved re-
NX
mote control button
RD
Rolling/fixed code decoding off
OAB
Gate left open
AT
Gate in self-calibration
List of alarms
Alarm
Description
XXXX
Reset card
Manoeuvre interval since last maintenance
MNP
reached alarm
F0
Error motor not selected
F1
Motor 1 cables inverted error
F2
Motor 2 cables inverted error
F3
Reversed limit switch error
F4
Both open limit switch alarm
F5
Opening limit switch malfunction error motor 1
F6
Closing limit switch malfunction error motor 1
F7
Opening limit switch malfunction error motor 2
F8
Closing limit switch malfunction error motor 2
F9
Communication error with expansion card
F10
Error alarm motor 1 not connected
F11
Error alarm motor 2 not connected
F12
Motor 1 encoder error alarm
F13
Motor 2 encoder error alarm
Microswitch undervoltage (check power supply
F14
and outputs)
F15
Safety test 1 failed
F16
Safety test 2 failed
F17
Safety test 3 failed
F18
Safety test 4 failed
F19
Motor 1 manoeuvre length/timeout alarm
F20
Motor 2 manoeuvre length/timeout alarm
F21
Motor 1 mosfet short alarm
F22
Motor 2 mosfet short alarm
F23
Blocked rotor alarm motor 1
F24
Blocked rotor alarm motor 2
F25
Overlapping leaf in closing alarm
F26
5th obstacle in closing alarm
F27
Overcurrent alarm motor 1
F28
Overcurrent alarm motor 2
F29
Radio memory full alarm
F30
Faulty radio memory alarm
F31
Short flashing alarm
F32
Gate open light short alarm
F33
No memory card alarm
F34
FW checksum alarm
F36
Board temperature alarm

Updating Firmware:

The control panel is equipped with a USB port that is
used to update the control panel Firmware or the Wi-Fi
EMC.W communication module Firmware
Caution:
If the firmware updating procedure is not carried out prop-
erly it may damage the control panel or the Wi-Fi com-
munication module, make sure not to interrupt the mains
power supply during the update.
To perform the Firmware Update, consult the instructions
provided with the Firmware
EN
25

Publicidad

Tabla de contenido
loading

Tabla de contenido