Exit Diagnostic Mode

1.
If a diagnostic test is currently in process, press the operator button once to stop the test.

Note: To exit diagnostic test 1 (carousel diagnostic test), press and hold the operator button to stop the test and
return to diagnostic mode.
When the diagnostic test is stopped, press the operator button six times and hold on the sixth press. The operator
2.
panel displays [EXIT DIAGNOSTIC].
3.
Release the operator button. The autoloader exits diagnostic mode and the system resets.
Diagnostic Test 1 – Carousel Diagnostic Test
This test has two modes. The first mode evaluates the position of the carousel. The second mode evaluates the alignment of
the lift arm to the carousel.

Check the Position of the Carousel

This test verifies that the carousel is positioned correctly in the autoloader.
Make sure that the autoloader is in diagnostic mode. Refer to the
1.
Press and hold the operator button until the operator panel displays [01 CAROUSEL CHK DIAGNOSTIC].
2.
Release the operator button.
3.
4.
Press the operator button to rotate the carousel from the current bin position to the next bin position.

Note: Each time the carousel rotates, the operator panel displays the actual carousel position and the target
carousel position on the operator panel. The actual carousel position number is displayed as [A+00000], and the
target carousel position is displayed as [T+00000].
Repeat step 4 for each of the four carousel bins.
5.

Note: After the carousel rotates clockwise from bin 1 to bin 4, it rotates counterclockwise from bin 4 to bin 1.
Press and hold the operator button to exit the test and return to diagnostic mode.
6.

Check the Alignment of the Lift Arm to the Carousel

This test verifies that the lift arm aligns properly with each carousel bin.
Make sure that the autoloader is in diagnostic
1.
mode. Refer to the
Access and Select Diagnostic
section on page 16.
Tests
Press and hold the operator button until the
2.
operator panel displays [01 CAROUSEL CHK].
Release the operator button.
3.
Place a disc on the lift arm. Press the disc into the
4.
gripper while you press the disc release button.
5.
Press the operator button to rotate the carousel to
a bin.
2001475_A
Maintain the Producer III
Access and Select Diagnostic Tests
Gripper
section on page 16.
Disc Release Button
17