Descargar Imprimir esta página

Diagnostic Test 5 - Cycle The Lift Diagnostic; Exit Diagnostic Test Mode - Rimage Producer 7100N Manual De Instrucciones

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 61
3.
Access and select
diagnostic test 3 Refer to page 14. The operator panel displays [CALIBRATE
DIAGNOSTIC].
The lift arm moves to the supply bin, picks up the disc and then drops the disc into the supply bin. Then, the lift
arm moves back to its home position above the printer tray. When this cycle is complete, the autoloader restarts
and exits diagnostic tests mode.
Note: Diagnostic test 3 causes the autoloader to exit diagnostic tests mode when completed. To continue
performing diagnostic tests, refer to
Diagnostic Test 5 – Cycle the Lift Diagnostic
This diagnostic test cycles media between the carousel bins and the printer. During each cycle, the test locates the
index mark on the disc.
Tip: This diagnostic test uses the lift motor, printer, rotate motor, the carousel, carousel sensors, index sensor,
and the media sensor.
Important! Use a disc with an index mark. To create a disc with an index mark, refer to
Index Mark
on page 14.
1.
Open the front door.
2.
Place one or more discs with an index mark in any bin.
3.
Access and select
diagnostic test 5. Refer to page 14. The operator panel displays, [CYCLE LIFT cycle =
00000].
The lift arm moves down to the carousel and picks up the disc with an index mark on it. The printer tray opens.
The lift arm releases the disc on top of the printer tray. The lift arm picks up the disc and drops it into a bin in the
carousel.
Notes:
The lift arm starts to pick discs from bin 1. If a disc is not in bin 1, the lift arm proceeds to the next bin.
The test continues to cycle media until the operator button is pressed.
4.
Press the operator button to stop the test.
5.
To exit diagnostic tests, refer to

Exit Diagnostic Test Mode

Press the operator button 19 times and hold on the last press. The autoloader exits diagnostic test mode.
Note: To exit a test but remain in diagnostic test mode, press the operator button one time while the test is
running. (Diagnostic test 3 is an exception.)