Install the Electrical Outlet (cont.)
Determine the electrical outlet location. Locate the electrical outlet
within 12" (305 mm) of the toilet.
IMPORTANT! Do not plug the seat into the electrical outlet at this
time.
Install and ground the electrical outlet. This electrical outlet must
be a dedicated, nominal 120 VAC, 60 Hz circuit protected by a
minimum 15 A Ground-Fault Circuit-Interrupter (GFCI) or
Residual Current Device (RCD).
Temporary Connection
NOTICE: Unless the outlet cover screw is grounded through the
house wiring, attaching the adapter grounding screw tab to the
cover screw will NOT ground the unit. If there is any doubt
whether the cover screw is grounded, have it checked by a qualified
electrician or service professional.
A temporary connection with a two-prong adapter may be made
where local codes permit, provided the adapter is grounded.
Kohler Co.
5
1194356-2-A