Replacement Parts List; Troubleshooting Chart - Campbell Hausfeld HV2000 Serie Guia Del Usuario

Ocultar thumbs Ver también para HV2000 Serie:
Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

Operating Instructions and Parts Manual
Maintenance
Be sure the air filter is clean. A dirty air
filter restricts air flow and can cause the
motor to overheat.
IMPORTANT: Keep the unit at the
maximum distance from the spray area
to extend filter life.
Model HV2000
2
Filter
Housing
Thumbscrew
Figure 3

Replacement Parts List

Ref
No.
Description
1
Filter
Filter pack
2
Hose 15'
Hose 25'
3
Quick connect coupler
4
Stub hose
Accessories
Ref
No.
Description
1
5' Whip Hose (Use with any model)
2
Multi-Purpose Case

Troubleshooting Chart

Symptom
Poor air flow
Unusual grinding noise
MODEL HV2000
1. Remove the filter grille thumbscrew
with a screw driver to access the
filter (See Figure 3).
2. Clean the filter with mild soapy
water and pat dry.
3. Replace filter if built-up with paint.
3
1
HV2000
MP3021
MP3106
HV002200AV
Possible Cause(s)
1. Hose restricted or kinked
2. Restricted filter
Damaged turbine motor
For Information About This Product
Call 1-800-626-4401
Models HV2500 or HV3000
3
2
Figure 4
Part Number For Model Number
HV2500
HV012600AJ
HV012500AJ
HV002200AV
HA222503AV
Part Number
HV012400AJ
HV7008
Corrective Action
1. Keep air hose straight
2. Clean or replace filter
Contact Service Center
3
MODEL HV2500 AND HV3000
1. Squeeze and pull to remove both
filters (See Figure 4).
2. Clean the filter with mild soapy
water and pat dry or replace filter if
built-up with paint.
3. Squeeze and tuck to install filter.
4
HV3000
HV012600AJ
HV012500AJ
HV002200AV
HA222503AV
Qty
1
1
www.chpower.com
1
Qty
1
2
1
1
1
1

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

Hv3000 serie

Tabla de contenido