Operating Instructions
operation
beFore FirSt Start-Up
break-in proceDUre
(Complete this procedure before using
compressor for the first time. Once
completed, it is not necessary to repeat.)
1. Turn regulator knob fully clockwise
(to the right) to open air flow and
open drain valve.
2. Turn ON/OFF switch (
position (
).
3. Plug in power cord.
4. Turn ON/OFF switch (
position ( ) and run compressor for
30 minutes.
5. Turn ON/OFF switch (
position (
).
6. Unplug power cord.
7. Close drain valve.
The compressor is now ready for use.
beFore each Start-Up
operatinG proceDUre
1. Turn regulator knob fully counter
clockwise (to the left) to close air
flow.
2. Connect air hose to outlet of
regulator.
3. Turn On/Off Switch (
position (
).
4. Plug in power cord.
5. Turn On/Off Switch (
position ( ) and let compressor run
until it reaches automatic shutoff
pressure.
6. Attach tire chuck or tool to end of
hose.
7. Turn regulator knob clockwise (to
the right) to desired pressure of tool
being used.
Risk of
Bursting! This compressor
is designed to provide air
pressure up to 200 psi.
Most attachments are
designed to operate at a maximum
pressure of less than 125 psi. DO
NOT adjust the regulator to result
in output pressure greater than the
marked maximum pressure of the
attachment.
on/oFF cYclinG oF coMpreSSor
In the ON position ( ), the compressor
pumps air into the tank. When a
shut-off (preset "cut-out") pressure is
reached, the compressor automatically
shuts off.
If the compressor is left in the ON
position ( ) and air is depleted from
the tank by use of a tire chuck, tool,
www.chpower.com
etc., the compressor will restart
automatically at its preset "cut-in"
pressure. When a tool is being used
continuously, the compressor will cycle
on and off automatically.
In the OFF position (
switch cannot function and the
compressor will not operate. Make
sure switch is in OFF position (
connecting or disconnecting power cord
from electrical outlet.
) to OFF
preSSUre GaUGeS
The gauge attached to control panel
) to ON
is the Outlet Gauge, and it indicates
air pressure going to hose (and tool
attached to end of hose).
) to OFF
The gauge toward the front of the
shroud is the Tank Gauge, and it
indicates air pressure in tank.
Maintenance
aSMe SaFetY valve
the safety valve!
Check the safety valve by performing
the following steps:
1. Plug the compressor in and run until
shut off pressure is reached (see
) to OFF
Operating Procedure).
2. Wearing safety glasses, pull the ring
on the safety valve (see Figure 5) to
) to ON
release pressure from compressor
tank. Use your other hand to deflect
fast-moving air from being directed
toward your face.
Figure 5
3. The safety valve should
automatically close when pressure
in the tank has been released. If the
safety valve does not allow air to be
released when you pull on the ring,
or if it does not close automatically,
it MUST be replaced.
cannot be actuated or it leaks air
after ring is released.
General
power before making any repair.
1. Check compressor for any visible
problems, especially check air filter
to be sure it is clean.
2. Pull ring on safety valve and allow
), the pressure
cannot be actuated or it leaks air after
ring is released.
3. Daily with compressor shut off:
) when
Figure 6
note: Tank should be emptied
regularly.
Do not remove or
tank under pressure.
attempt to adjust
4. Turn power OFF (
note: The air filter in the filter
housing on the side of the head must
be checked and cleaned periodically,
more often if used under very dusty
conditions or when a great deal of fog
from spraying is allowed to circulate
near unit.
iMportant: Unit should be located as
far from spraying area as hose will allow
to prevent over-spray from clogging
filter.
Filter reMoval, inSpection anD
replaceMent
Refer to this unit's replacement parts
manual for location of filter assembly
parts. To change a filter, remove the
screw in the filter housing cover. If filter
element is dirty, rotate filter element
so the holes line up with clean element
material and snap cover onto housing.
If filter element has no clean areas,
replace element.
Safety valve must
lUbrication
be replaced if it
This is an oilless type compressor
requiring no lubrication.
therMal overloaD protector
Turn off the pressure switch or unplug
Release all pressure
compressor for 20 minutes and allow it
and disconnect
to cool. Reset the unit. Switch unit to
OFF (
work.
6
it to snap back to normal position
(Figure 5).
Safety valve must
be replaced if it
Depressurize system prior to
draining tank. Drain moisture
from tank by opening drain valve
underneath the tank.
Do not remove
drain plug with
) and clean dust
and dirt from motor, tank, air lines
and pump cooling fins.
) and turn ON again to resume