Injector diameter and adjustment table (Table 6)
FAMILY/GAS
G-110
G-120
1
G-130
G-150
G-20
G-25
2
G-25.1
GZ-35
28 mbar
G-30
50 mbar
3
37 mbar
G-31
50 mbar
FAMILY/GAS
G-110
G-120
1
G-130
G-150
G-20
G-25
2
G-25.1
GZ-35
28 mbar
G-30
50 mbar
3
37 mbar
G-31
50 mbar
SUPPLY
VOLTAGE
230V 50-60Hz
* Cap type bypass: Standard bypass without interior part to let all gas flow pass.
Lower
BURNER - 700
calorific
∅ Injector
(mm.)
value
3.515
3.746
3,05
5.960
4.532
8.573
7.372
1,7
7.000
5.851
2,35
1,1
10.901
0,9
1,1
11.066
0,9
Lower
BURNER - 900
calorific
∅ Injector
(mm.)
value
3.515
3.746
4,6
5.960
4.532
8.573
7.372
2,25
7.000
5.851
3,05
1,45
10.901
1,25
1,45
11.066
1,25
Electrical instalation (Table nº7)
CABLE
SECTION
2x1,5mm²+T
ELECTRICAL OUTPUT KW
PILOT
∅ Injector (mm.)
H(mm)
Regulated
15-20
3/4 turn
0.40
20
Regulated
1/4 turn
30
0.25
25
0.20
30
0.25
25
0.20
PILOT
∅ Injector (mm.)
H(mm)
Regulated
15 -20
3/4 turn
0.40
25
Regulated
1/4 turn
30
0.25
25
0.20
30
0.25
25
0.20
POWER
DIFFERENTIAL
SWITCH
FUSE
4A
21
VALVE BYPASS
∅ (mm.)
Regulated
turnS
2
Regulated
turn
1/4
Regulated
turn
1/2
0,8
0,7
0,8
0,7
VALVE BYPASS
∅ (mm.)
Cap type and 5
turns opened*
Regulated 1/4 turn
Regulated 3/4 turn
1
0,9
1
0,9
DEVICE
30mA
0,1Kw