DIMENSIONS
MODELS
F10T-63EM
30 x 60 x 29h
F10T-63ET
30 x 60 x 29h
60 x 60 x 29h
F2/10T-66EM
F2/10T-66ET
60 x 60 x 29h
F13-64ET
40 x 60 x 90h
DIMENSIONS
MODELS
F10T-63ET
30 x 60 x 29h
60 x 60 x 29h
F2/10T-66ET
The data plate is attached to the back panel (see drawing electrical connection point) and contains all the
information necessary for connection.
When fitting, the appliance must be levelled using a spirit level; slight differences of level can be adjusted by screwing
or unscrewing the adjustable feet. The main switch or the socket must be near the appliance and easily accessible. It is
advisable to place the appliance under an extractor hood so that steam is extracted rapidly. If the appliance is placed
near walls, dividing panels, kitchen furniture, decorative finishing, etc. , these should be in flameproof material;
otherwise it is necessary to cover them with non-flammable material.
Above all, it is necessary to ensure that the fire prevention norms are observed.
During installation it is necessary to observe a maximum distance between the front edge of the supporting cabinet and
the appliance.(See diagram in item "Emptying the tub").
The installation, starting up and maintenance of the appliance must be carried out by qualified personnel. All operations
done when installing must be carried out observing the norms in force.
The manufacturer declines all responsibility in the event of incorrect functioning due to wrong installation or
installation which does not comply with the norms.
Attention! In accordance with international rules, when connecting the appliance, an automatic device enabling the
disconnection of all contacts from the mains, must be installed above it.
Installation must be carried out observing the following norms:
- Safety prescription in force
- Installation prescription in force.
The appliance is supplied without the connection cable.
To install the power supply cable, proceed as follows:
•
Remove the back panel
•
Push the connection cable through the cable blocker, connect the conductor wires to the corresponding terminals in
the junction box and fix them into place.
•
Block the cable with the cable blocker, and reassemble the back panel. The earth wire must be longer than the
others so that if the cable blocker should break, it will disconnect after the tension wires.
GB
TECHNICAL DATA TABLE
POWER SUPPLY
cm
230V~ 50/60 Hz
400V~3N 50/60 Hz
230V~ 50/60 Hz
400V~3N 50/60 Hz
400V~3N 50/60 Hz
TRANSFORMATION
POWER SUPPLY
cm
230V~3 50/60 Hz
230V~3 50/60 Hz
INSTRUCTIONS FOR INSTALLATION
INSTALLATION
LAWS, TECHNICAL RULES AND NORMS
ELECTRIC CONNECTION
IE
MAXIMUM
MAXIMUM
ABSORBTION
A
17,39
10,36
34,78
20,72
17,32
MAXIMUM
MAXIMUM
ABSORBTION
POWER
A
17,95
35,9
19
POWER
POWER
SUPPLY CABLE
kW
(Silicone)
4
3 x 2,5 mm²
7,15
5 x 1,5 mm²
8
3 x 6 mm²
14,3
5 x 2,5 mm²
11,95
5 x 2,5 mm
POWER
SUPPLY CABLE
kW
(Silicone)
7,15
4 x 2,5 mm²
14,3
4 x 6 mm²
2