Declaration Of Compliance; Technical Data Table; Instructions For Installation - Lotus F10D-64ET Instrucciones Para La Instalación Y El Uso

Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

The manufacturer declares that the appliances are compliant with the prescriptions of the EEC norm 90/396. The
installation must be done observing the norms in force particularly concerning room ventilation and discharging gas
emissions.
N.B.: The manufacturer declines any responsibility for direct or indirect damage caused by improper or incorrect
installation, alterations, maintenance or use of the appliance, as in all the other cases considered in the items of our sales
conditions.
MODELS
POWER SUPPLY
400V~3N 50/60Hz
F10D-64ET
F2/10D-66ET
400V~3N 50/60Hz
400V~3N 50/60Hz
F18D-64ET
F2/8D-64ET
400V~3N 50/60Hz
F23D-66ET
400V~3N 50/60 Hz
MODELS
POWER SUPPLY
F10D-64ET
230V~3 50/60Hz
230V~3 50/60Hz
F2/10D-66ET
F2/8D-64ET
230V~3 50/60Hz
The data plate is on the side (see diagram in electric connection item) and has all the data necessary for the connection.
When fitting, the appliance must be levelled using a spirit level; slight differences of level can be adjusted by screwing
or unscrewing the adjustable feet. The main switch or the socket must be near the appliance and easily accessibile. It is
advisable to place the appliance under an extractor hood so that steam is extracted rapidly. If the appliance is placed
near walls, dividing panels, kitchen furniture, decorative finishings, etc. , these should be in flameproof material;
otherwise it is necessary to cover them with non-flammable material.
Above all, it is necessary to ensure that the fire prevention norms are observed.
During installation it is necessary to observe a maximum distance between the front edge of the supporting cabinet and
the appliance.(See diagram in item "Emptying the tub").
The installation, starting up and maintenance of the appliance must be carried out by qualified personnel. All operations
done when installing must be carried out observing the norms in force.
The manufacturer declines all responsibility in the event of incorrect functioning due to wrong installation or
installation which does not comply with the norms.
Attention! In accordance with international rules,when connecting the appliance,an automatic device enabling the
disconnection of all contacts from the mains, must be installed above it.
GB

DECLARATION OF COMPLIANCE

TECHNICAL DATA TABLE

MAXIMUM
ABSORBTION A
10,36
20,72
22,95
17,39
20,64
TRANSFORMATION
MAXIMUM
ABSORBTION A
17,95
35,9
30,12

INSTRUCTIONS FOR INSTALLATION

INSTALLATION
20
IE
MAXIMUM
POWER SUPPLY CABLE
POWER kW
7,15
14,3
15,9
12
14,3
MAXIMUM
POWER SUPPLY CABLE
POWER kW
7,15
14,3
12
(Silicone)
5 x 1,5mm²
5 x 2,5 mm²
2
5x2,5 mm
2
5x2,5 mm
5 x 2,5 mm²
(Silicone)
4 x 2,5 mm²
4 x 6 mm²
2
4x4 mm