Installation Place
• A place which provides the spaces around the indoor unit as shown in the
diagram
• A place where there are no obstacles near the air inlet and outlet
• A place which allows easy installation of the piping to the outdoor unit
• A place which allows the front panel to be opened
• The indoor unit shall be installed as top of the indoor unit comes to at least
2 m height. Also, it must be avoided to put anything on the top of the indoor
unit.
CAUTION
• Direct sunlight to the indoor unit's wireless receiver should be avoided.
• The microprocessor in the indoor unit should not be too close to RF
noise sources.
(For details, see the owner's manual.)
Remote control
• A place where there are no obstacles such as a curtain that may block the
signal from the indoor unit
• Do not install the remote control in a place exposed to direct sunlight or close
to a heating source such as a stove.
• Keep the remote control at least 1 m apart from the nearest TV set or stereo
equipment. (This is necessary to prevent image disturbances or noise
interference.)
• The location of the remote control should be determined as shown below.
(Side view)
(Top view)
Remote
Reception
control
range
Cutting a Hole and Mounting
Installation Plate
Cutting a hole
When installing the refrigerant pipes from the rear
80 100
The center of the pipe hole
is above the arrow.
1. After determining the pipe hole position on the mounting plate (
pipe hole (Ø65 mm) at a slight downward slant to the outdoor side.
NOTE
• When drilling a wall that contains a metal lath, wire lath or metal plate, be sure
to use a pipe hole brim ring sold separately.
Mounting the installation plate
Anchor bolt holes
Hook
170
C
85
D
Hook
Pipe hole
Thread
Indoor unit
INDOOR UNIT
INDOOR UNIT
Indoor unit
Remote
control
180
Pipe hole
65 mm
100 mm
62
A
B
82.5
1
Hook
Installation
plate
Pipe hole
7
Mounting screw
Weight
When the installation plate is directly mounted
on the wall
1. Securely fi t the installation plate onto the wall by screwing it in the upper and
lower parts to hook up the indoor unit.
2. To mount the installation plate on a concrete wall with anchor bolts, use the
anchor bolt holes as illustrated in the below fi gure.
3. Install the installation plate horizontally in the wall.
CAUTION
When installing the installation plate with a mounting screw, do not use the
anchor bolt holes. Otherwise, the unit may fall down and result in personal
injury and property damage.
Installation plate
(Keep horizontal direction.)
5 mm dia. hole
CAUTION
Failure to fi rmly install the unit may result in personal injury and property
damage if the unit falls.
• In case of block, brick, concrete or similar type walls, make 5 mm dia. holes
in the wall.
• Insert clip anchors for appropriate mounting screws 7.
NOTE
• Secure four corners and lower parts of the installation plate with 4 to 6
mounting screws to install it.
1. The supply voltage must be the same as the rated voltage of the air condi-
tioner.
2. Prepare the power source for exclusive use with the air conditioner.
NOTE
• Wire type : More than H07RN-F or 245 IEC66
CAUTION
• This appliance can be connected to the mains in either of the following
two ways.
(1) Connection to fi xed wiring:
A switch or circuit breaker which disconnects all poles and has a
A
), drill the
contact separation of at least 3 mm must be incorporated in the fi xed
wiring. An approved circuit breaker or switches must be used.
(2) Connection with power supply plug:
Attach power supply plug with power cord and plug it into wall outlet.
An approved power supply cord and plug must be used.
NOTE
• Perform wiring works so as to allow a general wiring capacity.
3
7
Mounting screw
Ø4 x 25 R
Clip anchor
(local parts)
Electrical Work
Anchor bolt
Projection
15 mm or less