Removing:
Remove the screws and lift the CMAX carefully.
S
Mounting:
1. Check the seal and sealing surfaces and refit the
sub−base.
2. Screws must be fitted so that the self−cutting threads
can be used. Tighten the screws by hand in diagonally
opposite sequence. Tightening torque 0.9
3.3 Pin assignment of axis connection
X
12
Pin
Assignment
1
+24 V logic voltage
2
+24 V load voltage
3
0 V
4
CAN_H
5
CAN_L
Housing
Cable shield
Festo CPX−CMAX−C1−1 0902NH English
1.1 Nm.