Stihl HTA 65 Manual De Instrucciones página 42

Ocultar thumbs Ver también para HTA 65:
Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

English
Always remove the battery before carrying out any work on the machine.
Condition
Battery is not being charged even though
LED on charger glows green
LED on charger flashes red
1)
STIHL recommends an authorized STIHL servicing dealer.
40
Cause
Battery too hot / too cold
(1 LED on battery glows red)
No electrical contact between charger
and battery
Malfunction in battery
(4 LEDs on battery flash red for
about 5 seconds)
Malfunction in charger
Remedy
Allow battery to cool down / allow battery
to warm up slowly at temperatures of
about 15°C - 20°C (60°F - 70°F)
Operate charger only in closed, dry
rooms at ambient temperatures of 5°C to
40°C (40°F to 104°F)
Remove the battery and refit it
Take the battery out of the machine tool
and refit it. Switch on the machine – if the
LEDs continue to flash, the battery has a
malfunction and must be replaced.
Have charger checked by servicing
1)
dealer
HTA 65, HTA 85

Publicidad

Capítulos

Tabla de contenido
loading

Este manual también es adecuado para:

Hta 85

Tabla de contenido