Input Mode - Kübler CODIX 54P Instrucciones De Puesta En Servicio

Ocultar thumbs Ver también para CODIX 54P:
Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

3. Inputs
INP A
Dynamic count input.
INP B
Dynamic count input.
INP C
Dynamic frequency input.
4. Selection of the displayed value
Pressing the right key allows switching between
the totaliser display and the frequency meter
display. Press the key briefly to display for 2 sec-
onds the current function ("count" or "tacho"). If,
during this period of time, the right key is
pressed a second time, the device switches to
the current function and displays a confirmation
("count" or "tacho") for 2 seconds. Then, the
value of the selected function is displayed.
5. Setting of the operating parameters
a. Press both front side keys keys and switch
on the supply voltage or, if the supply voltage
is already on, press both keys simultaneous-
ly during 5 s.
b. The display shows
c. After releasing the keys, the display shows
c1.Hold the left key pressed and press the right
key to leave the programming operation.
c2.Press the right key to switch to
.
d. Hold the left key pressed and press the right
key to switch to the first parameter.
e. After releasing the keys, the display alter-
nates between the menu title and the current
menu item. After pressing any key, only the
menu item setting is displayed.
f. Pressing the right key, the menu item setting
will be switched to the next value. If figures
are to be input (e.g. when setting the scaling
factor), select first the decade using the left
key, and then set the value using the right
key.
g. Hold the left key pressed and press the right
key to switch to the next menu item.
h. The last menu title "EndPro" allows, when
selecting "Yes", to exit the programming
menu and to take over (store) the new val-
ues. If "no" is selected, the programming rou-
tine is repeated, the latest values set remain-
Page 4 | ENG
ing active. They can now be checked again
or modified.
6. Programming routine
The programmable parameters of the device are
described below, in the order in which they can
be set. The device is fully programmed after one
pass of the routine.
The first values stated correspond to the
factory settings
6.1 Polarity of the inputs
npn: switching for 0 V
pnp: switching for +U
6.2 Switching on the 30 Hz filter (INP A, INP B)
30 Hz filter off (f
30 Hzfilter on

6.3 Input mode

Count input and count direction
input
INP A: Count input
INP B: Count direction input
Differential input
IINP A: count input adding
INP B: count input subtracting
Totalising
INP A: count input adding
INP B: count input adding
Quadrature input
INP A: count input 0°
INP B: count input 90°
Quadrature input with pulse
doubling
INP A: count input 0°
INP B: count input 90°
Each pulse edge of INP A will
be counted
B
)
max

Publicidad

Tabla de contenido
loading

Tabla de contenido