Quadrature input with pulse
quadrupling
INP A: count input 0°
INP B: count input 90°
Each pulse edge of INP A and
INP B will be counted.
For the frequency
measurement, INP C may be
operated independently of the
counter input modes.
6.4 Multiplying factor (counter)
It can be set from 00.0001 up
to 99.9999.
The decimal point is set to 4
decimal places.
„0" is not accepted!
6.5 Dividing factor (counter)
It can be set from 00.0001 up
to 99.9999.
The decimal point is set to 4
decimal places.
„0" is not accepted!
6.6 Decimal point (counter)
The decimal point defines the
way of displaying the count val-
ues. It does not affect counting.
0
0.0
0.00
0.000
6.7 RESET Mode (counter)
manual reset via the red
RESET key
no reset (red RESET key
locked)
no decimal place
one decimal place
two decimal places
three decimal places
6.8 Multiplying factor (frequency meter)
It can be set from 00.0001 up
to 99.9999.
The decimal point is set to 4
decimal places.
„0" is not accepted!
6.9 Dividing factor (frequency meter)
It can be set from 00.0001 up
to 99.9999.
The decimal point is set to 4
decimal places.
„0" is not accepted!
6.10 Decimal point (frequency meter)
The decimal point defines the
resolution
0
0.0
0.00
0.000
6.11 Display mode (frequency meter)
Value conversion and
display in 1/s
Value conversion and
display in 1/min
6.12 Max. time to wait until „0" is displayed
(frequency meter)
This parameter indicates, how long it takes,
when measuring is active, until „0" is displayed.
Max. time to wait 00.1 s
(min. value)
Max. time to wait 99.9 s
no decimal place
one decimal place
two decimal places
three decimal places
Page 5 | ENG