7.
Problems and solutions
Below is a list of the problems that might arise, together with their respective causes and remedies.
If, after following the instructions below, the problem still persists,
distributor, the qualified installer or the manufacturer.
Description
No power supply
Selector in position 0
Temperature control
knob at °C
The machine
does not heat up
Main remote switch
fault
Safety thermostat
activation
Heating element
switched off
Safety thermostat
LED 1 does not
activation
light up when
selector in
position 1
Tip-up raised
Thermostat control
The oil
probe broken
temperature
does not
Thermostat control
correspond to
probe cable not
the set value.
connected correctly
8. Approximate time and temperature for industrial frying
The following table shows the temperatures and frying times, considered optimal for cooking some of the foods used in our
kitchens.
PRODUCTS
Fresh potatoes
Frozen potatoes (pre-cooked)
Frozen breaded mushrooms
Fresh eggplant breaded
Fresh shrimp breaded
Frozen shrimp breaded
Frozen cuttlefish breaded
Fresh fish fillet breaded
Frozen fish fillet breaded
Pork cutlets breaded
Veal cutlets breaded
Fresh chicken breaded
Frozen chicken breaded
Frozen chicken breasts breaded
Cause
Connect the machine to the electricity mains
Turn the selector to position 1 and set the required temperature.
Turn the temperature control knob to 190°C. If the problem persists: check the
emergency thermostat and reset this if necessary.
Check the electrical connections for the control thermostat; replace the thermostat if
necessary.
Check that all electrical connections are correct, if necessary, replace the contactor.
Reset the safety thermostat, which is housed at the base of the electrical panel by
pressing firmly
Check all the electrical connections. Replace the remote switch and/or the heating
element if necessary.
The oil temperature has exceeded 205 ° C. Wait until the oil temperature is lowered to
170 ° C and reset the safety thermostat which is housed at the base of the electrical
panel by pressing with force
The oil level in the tub is below the minimum level marked. Fill the right amount of oil or
fat until the minimum or maximum level marked on the tank. Reset the safety
thermostat located at the base of the cabinet.
Replace the safety thermostat if the problem persists if the temperature is lowered
200°C.
If the flap is raised, the LED 1 turns off. If the problem last even if the heating elements
is in the proper position, and the selector is on position 1, verify that the magnetic
connection works properly and eventually replace it.
Replace the thermostat control
Replace the thermostat control
TEMP. °C
175-180
180
175-180
175-180
180-185
180-185
175-180
175-180
175-180
175-180
175-180
180-185
175-180
175-180
please note down the code and contact the
Rimedies
TIME (min)
5-6
3-4
2-3
3-4
3-4
3-4
1,5-2
3-4
4-5
4-5
3-4
10-15
6-8
3-4
Rev. 0.00 / 2017 - pag. 16 di 47