//AJUSTE DEL ALCANCE DEL SENSOR
This flush valve was supplied with Stern's new Self Adjusting Sensor. The ideal detection range for the
specific location will be set automatically.
Only if necessary, use the remote control to adjust the sensor range as follows:
Detection range:
The detection range is the maximum distance at which an object can be located to be able to activate the
system.
In all SANINDUSA infrared products, the sensor range may change using this button on the remote
control.
Hold the remote control straight in front of the sensor in a
distance of about 4" (10cm). Choose the function RANGE by
pressing once at the range function button. After pressing
this function button, a quick flashing of the red light at the front
of the sensor will occur. At this stage, you can increase or
decrease the sensor range by pressing the (+) or the (-) buttons,
every push will increase or decrease one level.
Once you have changed the detection range with the remote control, this distance will be remembered by
the sensor, even if the power source is disconnected. To get back to the self adjustment mode, use the
ADJ button only
Self adjustment mode:
Check that no objects are in front of the sensor. Press the ADJ
button. Once a quick flashing of the red light of the sensor eye
is perceived, remove your hand holding the remote control
from the sensor area. The ideal sensor range for the specific
location will be set automatically. Ones the self adjustment
has taken place the solenoid valve will be opened and closed
for 1 second as an indication that the ideal sensor range
was set and the product is ready for use.