Disposal Note; Technical Data - Grohe Eurodisc SE 36 233 Manual Del Usuario

Ocultar thumbs Ver también para Eurodisc SE 36 233:
Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 13
GB
Application
Prod. no. 36 249 and 36 250:
Single-hole mixer suitable for:
• Direct connection to cold water supply
• Connection to outlet of mixed water supply
Prod. no. 36 233 and 36 251:
Can be used in conjunction with:
• Pressurised storage heaters
• Thermally controlled instantaneous heaters
• Hydraulically controlled instantaneous heaters
Operation with unpressurised storage heaters (displacement
water heaters) is not possible.

Technical Data

• Pressure
min. 0.5 bar / recommended 1 - 5 bar
• Operating pressure
• Test pressure
If static pressure is greater than 5 bar, fit a pressure-reducing
valve.
• Flow rate at 3 bar pressure:
• Supply voltage:
6 V-lithium battery (type CR-P2)
• Infinitely variable running time from 2 - 180 s
(factory setting: 15 s)
• Automatic safety shut-off after 180 s
• Pulsating water jet indicates battery change required soon
• Type of protection:
Prod. no. 36 233 and 36 251:
• Temperature
Hot water inlet:
Recommended (energy saving):
• Water connection
Note
Avoid major pressure differences between hot and cold water
supply.
Special accessory, see Replacement parts, fold-out page I.
• Special spanner (Prod no.: 19 132) for removal of flexible
hoses.
• Theft-proof aerator (Prod. no.: 36 133).
• Vandalism-inhibiting, concealed mixer spindle
(Prod. no.: 36 209).
• Vandalism-inhibiting, rotation lock (Prod. no.: 42 270).
The rotation lock is not suitable for products with pop-
up waste.
Approval and conformity
This product conforms to the requirements of the
relevant EU guidelines.
The conformity declarations can be obtained from the following
address:
GROHE Deutschland Vertriebs GmbH
Zur Porta 9
D-32457 Porta Westfalica

Disposal note

Dispose of the battery properly.
max. 10 bar
Installation
16 bar
Flush pipes thoroughly.
approx. 6 l/min.
Installation
Refer to the dimensional drawings on fold-out page I.
Lift rod (A) must be inserted into the mixer body during
IP 59 K
installation, see fold-out page II, Fig. [1].
Fasten fitting to basin, see Figs. [1] to [3].
max. 70 °C
Install pop-up waste (28 910), see fold-out page I.
60 °C
Seal plug-hole rim.
cold - right
hot - left
Connection
The cold water supply must be connected on the right and the
hot water supply on the left.
Screw adapter (B) together with seal (C) onto the service
valve, see Fig. [4].
In order to ensure permanent, trouble-free operation,
installation of the enclosed adapter with dirt strainer and
non-return valve is mandatory.
Open hot and cold water supply and check connections
for leakage.
4

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

Eurodisc se 36 249Eurodisc se 36 250Eurodisc se 36 251

Tabla de contenido