Work And Earth Connections; Torch Coolant Preparation - ESAB ESP-150 Manual De Instrucciones

Ocultar thumbs Ver también para ESP-150:
Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 69
SecTION 3
Operating the unit without coolant will
cause permanent damage to coolant
pump.
Do not use commercial antifreeze or tap
water. equipment will malfunction and
damage will occur.
3.6

WORK and eaRTh cONNecTIONS

1 .
Connect terminal lug end of the work cable assembly to stud on lower left corner
of front panel . Nut should be wrench tight . (Fig . 15) . Electrically connect work
cable to work piece . The connection must be made to a clean, exposed metal
surface free of paint, rust, mill scale, etc . (Fig . 15) .
2 .
Make sure workpiece is connected to an approved earth ground . Use copper
ground cable equal to or larger than the power supply chassis ground listed in
Table 1 .
3.7

TORch cOOlaNT PRePaRaTION

1 .
Remove the cap from the coolant filter tank . Fill coolant tank with 2 gallons (7 .5
liters) of plasma system coolant (P/N 156F05) - supplied with the package . The
coolant also provides antifreeze protection down to -34° .
Due to high electrical conductivity, use of tap water or commercial antifreeze is
NOT recommended for torch cooling . Use of tap water can result in algae growth
in the water cooler and torch . Automotive type antifreeze will adversely affect
starting and will form deposits in the torch that will cause damage .
2 .
With installation completed, check all gas and coolant fittings for leaks using a
standard solution .
PT-26
Work cable -
25 ft. - 23120589
50 ft. - 23120590
fig. 15 - access for filling Torch coolant Tank
25
INSTallaTION
TORCH COOLANT FILL
ACCESS
LEVEL INDICATOR
grounded
Work
Table
earth
ground

Publicidad

Tabla de contenido
loading

Tabla de contenido