Informes de seguridad de materiales (sólo en inglés)
SECTION 5 - FIRE FIGHTING MEASURES
FLASH POINT: Not applicable
FIRE & EXPLOSION HAZARDS: Toner is a combustible powder. Like most organic powders, it can form
explosive mixtures when dispersed in air.
EXTINGUISHING MEDIA: Water, dry chemical, carbon dioxide, or foam.
FIRE FIGHTING INSTRUCTIONS: Avoid inhalation of smoke. As for any fire, wear protective clothing and self-
contained breathing apparatus.
SECTION 6 - ACCIDENTAL RELEASE MEASURES
SPILL OR LEAK: Sweep up or vacuum spilled materials and carefully transfer into sealable waste container.
Sweep slowly to minimize generation of dust during clean up. If a vacuum is used, the motor must be rated as dust
tight. A conductive hose bonded to the machine should be used to reduce static buildup. Clean up residue if
necessary with soap and cold water. Wash or dry clean garments after removing loose toner.
SECTION 7 - HANDLING AND STORAGE
HANDLING: No special precautions, when used as intended.
STORAGE: Avoid high temperatures.
SECTION 8 - EXPOSURE CONTROL - PERSONAL PROTECTION
No special personal protection indicated, when used as intended in Xerox Phaser Ò laser printers.
THRESHOLD LIMIT VALUE (TLV): 10 mg/m3 (total dust)
PERMISSIBLE EXPOSURE LIMIT (PEL): 15 mg/m3 (total dust); 5 mg/m3 (respirable dust)
SHORT TERM EXPOSURE LIMIT (STEL): None established
CEILING LIMIT: None established
XEROX EXPOSURE LIMIT (XEL): 2.5 mg/m3 (total dust); 0.4 mg/m3 (respirable dust)
SECTION 9 - PHYSICAL AND CHEMICAL PROPERTIES
APPEARANCE/ODOR: Black powder/faint odor
BOILING POINT: Not applicable
SOLUBILITY IN WATER: Negligible
EVAPORATION RATE: Not applicable
VAPOR DENSITY (Air = 1): Not applicable
VOLATILE: Not applicable
SOFTENING RANGE: 85° to 100°C
MELTING POINT: Not available
SPECIFIC GRAVITY (Water = 1): Approximately 1.7 g/ml
VAPOR PRESSURE (mm Hg): Not applicable
pH: Not applicable
Impresora láser Phaser™ 4400
20