Without any key operation for 30s under the unlock state, the system
enters the lock state automatically. Except the key "DISPENSER" and
operation of filter rest, the operations of following keys must be
conducted under unlock state. For any operation under the lock state,
the lock icon will flash and prompt a buzzing sound for fault operation.
The following settings must be valid upon locking.
2. MODE.SEL
Press "MODE.SEL" for cycle setting of the mode "Holiday" → "Super
Freezing" → "Super Cooling + Super Freezing" → "Super Freezing" →
"None" → "Holiday"... Display panel and relative setting icon will
display/die out synchronously.
Holiday mode: Freezing chamber is operating upon the temperature
setting of -18°C and refrigerating chamber is off (not freezing).
(Closedown of refrigerating chamber has no effect on its lamp control)
Super Freezing mode: Freezing chamber is operating upon the
temperature setting of-24°C; the Super Freezing mode will exit
automatically after operation for 26h. Then, freezing chamber restores
to the valid temperature setting before Super Freezing mode. (Power off
and then on, the Super Freezing mode exits. After that, the set
temperature of freezing chamber is restored to -18°C)
Super Cooling mode: Refrigerating chamber is operating upon the
temperature setting of 2 °C; the Super Cooling mode will exit
automatically after operation for 150min . Then, refrigerating chamber
restores to the original temperature setting. (Power off and then on,
Super-cooling mode exits) After that, the set temperature of
refrigerating chamber restores to 5°C)
Press "FRZ. TEMP." or "REF. TEMP.", holiday mode exits; refrigerating
chamber and freezing chamber restore to original temperature settings;
Press "FRZ. TEMP.", Super Freezing mode exits; freezing chamber
restores to operation under the original temperature setting;
Press "REF.TEMP.", Super Cooling mode exits; refrigerating chamber
restores to operation under the original temperature setting;
Hold "MODE.SEL" for 2s to cancel/set the function of door-opening
sound. To power on the display panel for the first time, the system
defaults a sound for door opening. Press the key again to cancel the
sound of door opening. To open the door, the buzzer does not prompt a
sound (but the timeout warning of door opening is still valid).
95
3. REF.TEMP.
1) Temperature setting of refrigerating chamber
Press "REF.TEMP." key to choose refrigerating chamber, the
temperature setting of refrigerating chamber blinks; press
"REF.TEMP." again to set the temperature of refrigerating chamber;
set the refrigerating chamber circulating under the state of "8 → 7 →
6 → 5 → 4 → 3 → 2 → 8 →......" Without key operation, the area of
refrigerating temperature stops blinking after 5s.
4. FRZ.TEMP.
1) Temperature Setting of Freezing Chamber
Press "FRZ.TEMP." key to choose freezing chamber, the temperature
setting of freezing chamber blinks; press "FRZ.TEMP." again to set the
temperature of freezing chamber; set the refrigerating chamber
circulating under the state of "-16 → -17 → -18 → -19 → -20 → -21 →
-22 → -23 → -24 → -16......" Without key operation, the area of
refrigerating temperature stops blinking after 5s.
5. ICE OFF
Press "ICE OFF" key, the relative words and icon die out/lights up,
activating/inactivating the ice-making function.
6. DISPENSER
Press "DISPENSER" key to choose ice/water state; set it circulate
under the state of "Get IceCrushed IceGet Water None", the relative
icon on the panel will light up/die out in turns.
7. Ice-maker Water Intake Time Setting
Hold the composition key "FRZ.TEMP." + "REF.TEMP." for 2s to enter
the setting state; press "REF.TEMP." and "FRZ.TEMP." to increase or
decrease the grade of water intake for ice-marker (adjustable
between5-25s). (Setting time is displayed on the area of freezing
temperature). Enter the setting state of ice-maker water intake time
or holding the combination key "FRZ.TEMP." + "REF.TEMP." for 2s,
such mode may exit.
Announcements
The
refrigerator
use
alternating
is220-240V/50Hz. If the voltage fluctuations is large (Over the scope of
198-264V), it may cause some failures, such as the refrigerator does
not start, The main control board and compressor bum and the
current
supply
which
GB
96