5. Changing the Filters in CleanSpace2

the atmosphere.
CHANGING THE PRE-FILTER
We recommend changing the pre-filter daily. Prior to opening the filter cover and removing the pre-filter, clean the
outside of the Respirator with CleanSpace
the inside of the Power Unit. To unlock the filter cover lift the pin located on the end of the filter cover.
The filter cover should easily swing open exposing the used CleanSpace2
and replace with a new pre-filter, taking care not to disturb the particulate filter. Swing the filter cover back into its
closed position and press the pin down until clicked back into place.
CHANGING THE PARTICULATE FILTER
The particulate filter should be changed when the CleanSpace2
filter is blocked. To unlock the filter cover lift the pin located on the end of the filter cover. The filter cover should
easily swing open exposing the used CleanSpace
replace with a new CleanSpace
and press the pin down until clicked back into place.
Only CleanSpace
The CleanSpace
filters are NOT reusable and should NOT be cleaned. Do not use compressed air or any other
method to clean the CleanSpace filters. Cleaning the filters affects the filtering efficiency and reduces the
protection factor.
The markings on these filters in relation to EN12942 must not be confused with markings on filters related to any
other standard.
DO NOT FORCE THE FILTER COVER OPEN BEYOND 90
Cleaning Wipes or a damp cloth to prevent potential contamination of
particulate filter and pre-filter. Swing the filter cover back into closed position
filters and pre-filters should be used with the CleanSpace2
IT IS ESSENTIAL THAT THE CORRECT FILTER TYPE IS SELECTED
FOR THE CHOSEN APPLICATION.
Before using CleanSpace2
you are using the correct filter type for the environment
you are working in. The CleanSpace2
supplied with a particulate filter.
Before changing the filter on the Respirator, move out
of the contaminated area and remove the Respirator.
Used filters should be disposed of responsibly and
treated as non-recyclable hazardous* waste (*
dependent on the contaminant being filtered). Filters
need to be regularly changed. The frequency of change
depends on use and concentration of contaminants in
pre-filter. Remove the used pre-filter
filter alarm alerts the wearer that the particulate
filter. Remove the used filter (and pre-filter, if applicable) and
8
you should ensure that
Power Unit is
O
Respirator.