Notes on digital operation
• Note: Please note that not all functions are possible in all
digital protocols. Several settings for functions, which are
supposed to be active in analog operation, can be done
under DCC.
General Note to Avoid Electromagnetic Interference:
A permanent, flawless wheel-rail contact is required in
order to guarantee operation for which a model is designed.
Do not make any changes to current-conducting parts.
CV
Discription
1
Address
4
Braking delay
8
Reset
17
Extendet address (upper part) (CV 29, Bit 5=1)
18
Extendet address (lower part) (CV 29, Bit 5=1)
Bit 0: Travel direction polarity reversal
Bit 1: number of speed levels 14 – 28/126
29
Bit 2: DCC Operation with braking Block
DCC-, Selectrix and DC power operation
Bit 5: address size 7 Bit / 14 Bit
Factory
DCC Value
Setting
1 – 127
3
1 – 127
3
8
131
0 – 255
192
0 – 255
0
0 – 255
6
7