Troubleshooting - Schumacher Electric SI-200A Manual Do Usuário

Cargador de baterías automático
Ocultar thumbs Ver también para SI-200A:
Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

15.

TROUBLESHOOTING

PROBLEM
Battery connectors do
not spark when touched
together.
The charger is making
an audible clicking
sound.
CHECK BATTERY
(red) LED is on.
CHECK BATTERY
(red) LED is blinking.
Charger will not turn
on when properly
connected.
The battery is connected
and the charger is on,
but is not charging.
16.
SPECIFICATIONS
Input
Output
Dimensions (H x W x D)
Weight
Output Protection
Reverse Polarity Protection, Spark/Arc Proof
POSSIBLE CAUSE
The charger is equipped with an
auto-start feature. It will not supply
current to the battery connectors
until a battery is properly connected.
Meaning, the connectors will not
spark if touched together.
Circuit breaker is cycling.
Battery is defective.
Shorted battery cables or
connectors.
Severely discharged battery, but
otherwise it is a good battery.
Reverse connections at battery.
Connectors are not making a good
connection to the battery.
Connections are reversed.
Battery is defective (will not accept
a charge).
Indicates the charger is in abort
mode.
AC outlet is dead.
Poor electrical connection.
Connectors are not making a good
connection.
No problem; this is a normal condition.
The settings may be wrong. Check the
charger settings.
Have the battery checked.
Circuit breaker cycles when current draw
is too high. Check for shorted cables or
connectors and replace if necessary.
The battery may not want to accept a
charge due to a run-down state. Allow
charging to continue until battery has a
chance to recover sufficiently to take a
charge. If more than 20 minutes, stop
charging and have the battery checked.
Shut the charger off and correct the lead
connections.
Check for poor connection to battery and
frame. Make sure connection points are
clean. Rock connectors back and forth
for a better connection.
Unplug the charger and reverse the
connectors.
Have battery checked.
See "Aborted Charge" in the
OPERATING INSTRUCTIONS Section.
Check for open fuse or circuit breaker
supplying AC outlet.
Check power cord and extension cord for
loose fitting plug.
Check for poor connection at battery and
frame. Make sure connecting points are
clean. Rock connectors back and forth
for a better connection.
120–240V~, 50/60Hz, 0.47–0.28A
12V
188 mm x 84 mm x 72 mm
0.54 kg
Yes
Yes
27
REASON/SOLUTION
2A