When disconnecting the charger, always do so in the reverse order of the connecting
procedure and break the first connection while as far away from the battery as practical.
7.8
A marine (boat) battery must be removed and charged on shore. To charge it onboard
requires equipment specially designed for marine use.
8.

GROUNDING AND AC POWER CORD CONNECTIONS

plug pins must fit the receptacle (outlet). Do not use with an ungrounded system.
8.2
have a proper grounded outlet installed by a qualified electrician. An improper
connection can result in a risk of an electric shock or electrocution.
8.3
Recommended minimum AWG size for extension cord:
• 100 feet (30.5 meters) long or less – use an 18 gauge (1.0 mm
• Over 100 feet (30.5 meters) long – use a 16 gauge (1.25 mm
9.
FEATURES
4
10.
ASSEMBLY INSTRUCTIONS
Remove all cord wraps and uncoil the cables prior to using the battery charger.
11.

CONTROL PANEL

LED Indicators
CHECK BATTERY
connected to the battery.
CHECK BATTERY
CHARGING
and is charging it.
CHARGED
is in maintain mode.
NOTE: See the Operating Instructions section for a complete description of the
charger modes.
12.
OPERATING INSTRUCTIONS
the assembly instructions before it is used.
The charger does not have an ON/OFF switch. The On and Off commands are controlled
by plugging the SI-200A into an AC electrical wall outlet only after the battery connections
have been made. See the warning label on the charger for the correct input voltage.
RISK OF ELECTRIC SHOCK OR FIRE.
8.1
This battery charger is for use on either a nominal 120V,
50/60 Hz or a nominal 120-240V, 50/60 Hz circuit. (See the
warning label on the charger for the correct input voltage.) The
plug must be plugged into an outlet that is properly installed and
grounded in accordance with all local codes and ordinances. The
Never alter the AC cord or plug provided – if it does not fit the outlet,
5
1
(red) LED lit: Indicates that the charger is not properly
(red) LED flashing: Indicates the charger is in abort mode.
(yellow) LED lit: Indicates the charger has detected a battery
(green) LED lit: Indicates the battery is fully charged and the charger
This battery charger must be properly assembled in accordance with
6
1. CHARGING Indicator
2. CHARGED Indicator
3. CHECK BATTERY Indicator
4. Battery Clips
5. Ring Terminal Connectors
6. 12 Volt Power Plug Connector
2
3
24
) extension cord.
2
) extension cord.
2

Publicidad

Tabla de contenido
loading

Tabla de contenido