14. Remove the pump assembly from the pump tray and
set pump aside. Wipe or rinse out pump tray and wipe
dry.
15. Remove pumpout hose from the check valve outlet.
16. Unscrew check valve. Using needle nose pliers,
carefully remove bottom of check valve assembly by
inserting one side of pliers approximately ⅛ in. into hole,
grasp and pull out carefully. A small ball bearing should
fall out so be careful not to lose it. Inspect assembly for
debris in assembly and clean accordingly. Reinstall the
ball bearing and reinstall the check valve assembly.
Reassemble in reverse order. The dehumidifier is now
ready for use.
Annually
Have the pump system inspected by a qualified service
center.
TRANSPORTATION AND STORAGE
IMPORTANT: Before moving, transporting or
storing, purge unit and stow hose and power cord as
described in the "At the End of the Job" section
above.
NOTICE: Handle the unit carefully. Do not drop, throw or
place the unit where it could fall. Rough treatment can
damage the dehumidifier and may create a hazardous
condition or void the warranty.
• Do not expose the control panel to moisture, snow
or rain.
• Store and transport securely to avoid any damaging
impact to internal parts.
• Secure during transport to prevent sliding and
possible injury to vehicle occupants.
FIG. E: ELECTRIC BOX
ATTACHMENT SCREWS
1. After placing a firm support under the base of the unit, remove
the center hub cap and remove the axle nut. The wheel will now
slide off. 2. Remove the two screws (shown in the circles above) to
detach the electric junction box.
110489Q #110128 (F410), #110133 (F411)
• Do not transport or store the unit on its front, sides or
back. This will help to prevent any remaining moisture
from escaping from the unit or flowing into areas
outside the sump.
CLEANING COILS AND HEAT
EXCHANGE BLOCK
WARNING! Unplug unit before servicing.
To help keep the unit operating efficiently, keep the coils
and the air-to-air heat exchange block clean. Access
these components by removing the side and rear covers:
1. Unplug unit.
2. Unplug the power cord from the socket at the base of
the unit. Remove pump hose at quick-connect.
3. Remove filter.
4. Remove both side covers A and B (unscrew two bolts
shown for each panel).
5. Remove back cover (unscrew the four bolts shown on
the back and the two bolts on the upper front panel).
6. Remove the heat exchange block.
Inspect the heat exchange block carefully. If necessary,
use compressed air to clear the channels of the block,
taking care not to damage the block.
NOTICE: The unit is fitted with sensitive electronic
sensors. Protect the sensors from impact and do not
expose them to water or cleaning solution.
Vacuum or use compressed air on both sides of the
upright (condenser) coil until it is clean. Take care not to
let the nozzle touch the fins; as this may damage the
fins. A coil cleaner product may be used on the
horizontal cold (evaporator) coil only. Follow instructions
on product label. Take care not to spray or wipe product
on or near any electrical components or sensors. To
FIG. F: ELECTRIC BOX LOCATION
After removing attachment screws (Fig. E), tilt the bottom of the
electrical box to the right and slide it out. Set aside. It is not necessary
to disconnect any electrical cables.
7
Legend Brands, Inc.