Connection to the gas supply
gasket
fig. 2
A Connect the gas hob using a 12 mm diameter rigid copper pipe, as shown in fig. 2. To
B Connect the hob using a continuous-surface steel hose. Once again, in this case,
Having completed the connection to the gas supply, use soapy water to check the
connection for leaks.
For United Kingdom, Northern Ireland and Republic of Ireland
gasket
flexible steel hose
copper pipe
Ventilation of installation area
Make sure that the room where the appliance is installed has permanent ventilation
openings on an outside wall or ventilation ducts, in order to ensure adequate air flow as
prescribed by current legislation. All openings must:
1. have a minimum working section of 100 cm
2. be made in such a way as prevents them being blocked in any manner, from inside or outside;
3. be provided with suitable protection to ensure the size of the ventilation opening is not
4. be positioned at such a height from floor level as not to interfere with the discharge of
If openings are made in the wall of an adjacent room, the latter must have direct
ventilation and must not be:
1. a bedroom
2. a common area of the building in question
3. a fire hazard area
Before testing and inspecting the appliance check that the adjacent room, which shares
the wall in which the ventilation opening has been made, does not have low pressure due
to another user; moreover, ensure adequate air flow between the two rooms is
guaranteed by permanent, unobstructed openings, for example by increasing the gap
between the bottom of the door and the floor. Discharge of combustion products must be
guaranteed by means of a hood which, in turn, must be connected to a chimney, a flue, or
directly to the outside.
Accessing the hob
To access the box containing the functional parts, proceed as follows:
• remove the grids, burner caps and flame-spreaders;
• remove the knobs, pulling them off their pins;
• remove the screws that fix the burners to the hob;
• lift the hob.
16
gasket
copper pipe
prevent any risk of leaks, use the rubber gasket supplied.
prevent any risk of leaks by using the gasket supplied. Note that installation must be
carried out in compliance with current regulations pertaining to gas installations.
reduced;
combustion fumes.
Check that the appliance is suited to the gas type
before connecting it to the gas supply in
steel hose
flexible
conformance with current legislation.
If this is not the case, carry out the operations
described in the paragraph on "replacing injectors"
(page 17). For a liquid gas supply use pressure
regulators which comply with current legislation.
Connection to the gas supply may be made in two ways:
2
;