Electrical connection
The FRANKE cooking hob comes with a 3-core power cable with free terminals.
If the hob is permanently connected to the power supply, install a circuit breaker having a
contact opening distance (at least 3 mm) that allows complete disconnection in the
conditions of overvoltage category III. Make sure:
a)the plug and socket are suitable for a 16A current
b)both are easily accessible and positioned so that no live part can be accessed when
inserting or removing the plug
c)the plug can be inserted without difficulty
d) that when the plug is inserted, the hob is not resting on it when installed in the cabinet
e)the terminals of two appliances are not connected to the same plug
f)
if the power cable needs to be replaced use a 3 x 1.5 mm2 cable type H05VV-F
g )to respect the polarities of the free terminals
(Brown=Live Blue=Neutral Yellow/Green=Earth)
NB: Make sure the characteristics of your household
electrical system (voltage, maximum power and current)
are compatible with those of your FRANKE hob.
Replacing injectors
NB: All the appliances are factory-set for G20 natural gas (methane).
If a different type of gas is to be used, change the injectors as follows:
1. remove the grids, burner caps and flame-spreaders;
2. unscrew and remove the injectors and replace them with those supplied, suitable for
3. refit the flame-spreaders, burner caps and grids;
4. these burners do not require air adjustment.
Important
When converting the appliance to a different type of gas, place the corresponding self-
adhesive label (supplied as an accessory) in the special space on the dataplate. For
operation with LPG. (G30 or G31), the minimum flame screw must be fully screwed
down. These appliances are supplied in cat. II 2H3+
Minimum flame adjustment
- Remove the knobs (push-on type).
- Light the burners and adjust the minimum flame by
the gas supply, making sure the marking matches that given in the table (page 18);
turning the adjustment screw clockwise to reduce
the flame and anticlockwise to increase it (fig. 3).
The screwdriver for adjustment is supplied with
the accessories.
Highest minimum
setting
Lowest
minimum
setting
fig. 3
17